Fortress Bridge: Monitoring and Diagnostics
78
Stat2
can exhibit:
solid green
- The Bridge is operating in root mode.
off
- The Bridge is operating in non-root mode.
Clr
can exhibit:
fast green flash
- The Bridge is passing cleartext
(unencrypted data) in the encrypted zone.
Fail
can exhibit:
off
- The
Fail
LED does not apply to version 2.6.
x
of the
Fortress Bridge software. It is reserved for future support
for failover Bridge deployments.
Pwr
can exhibit:
solid green
- The Bridge is powered on, either through the
+48V DC adapter inlet or the WAN port’s PoE connection.
off
- Bridge is powered off.
5.6.2
Radio LEDs
The Bridge’s internal radios are each associated with a pair of
front-panel LEDs, labeled
Radio1
and
Radio2
.
Radio LEDs are arranged one above the other. Each radio then
has an associated
upper
and
lower
LED.
When the radio’s
LED RSSI Monitor
is
Disabled
(the default) the
Radio1
and
Radio2
LEDs behave as shown below. (The
LED
RSSI Monitor
and associated LED behaviors are described in
The upper LED can exhibit:
intermittent green flash
- The radio is passing traffic.
The lower LED can exhibit:
solid green
- The meaning depends upon the radio’s mode
settings:
In
AP
or
Root Bridge
modes - The radio is active and
acting as an AP or a root Bridge.
In
Non-Root Bridge
mode - The radio is connected to the
root Bridge.
off
- This state is meaningful only for a radio in
Non-Root
Bridge
mode and indicates that the radio is not connected
to the root Bridge.
color/behavior
upper LED
lower LED
both LEDs
all four LEDs
solid green
n/a
in
AP
or
Root Bridge
modes:
active
in
Non-Root Bridge
mode:
connected to root
n/a
n/a
intermittent green
passing traffic
n/a
n/a
n/a
solid amber
n/a
n/a
n/a
firmware error
off
n/a
in
Non-Root Bridge
mode:
not connected to root
radio
disabled
both radios
disabled