background image

 
JSC FORTEZA 

                                                     FORTEZA FM-30(24)-BT 

Please visit our internet sites:  

                       

www.forteza.com

    or    

www.forteza.eu

         Page 1 

 

 
 
 
 
 
 
 

 

 

Security Sensors 

FM-30(24)-C-BT 
FM-30(24)-V-BT 

FM-30(24)-F-BT 

 

User manual 

Document Part Number 4372-43071246-087-07 

 

Declaration of conformity 

ЕАЭС № RU Д-RU.ГР01.В.06594 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

2017 

Summary of Contents for FM-30(24)-C-BT

Page 1: ...se visit our internet sites www forteza com or www forteza eu Page 1 Security Sensors FM 30 24 C BT FM 30 24 V BT FM 30 24 F BT User manual Document Part Number 4372 43071246 087 07 Declaration of conformity ЕАЭС RU Д RU ГР01 В 06594 2017 ...

Page 2: ...n 6 6 Sensor construction 6 7 Safety measures 10 8 Mounting 10 8 1Requirements for the protected site 10 8 2Requirements for the protected building 11 8 3Mounting on the perimeter site 11 8 4Mounting on the wall 14 9 Preparation for the operation 14 10 Adjustment with a PC 17 11Adjustment with Bluetooth 30 12 Maintenance 38 13 Troubleshooting guide 39 14 Storage 40 15 Transportation 40 16 Acceptan...

Page 3: ...operation Sensor components and possible delivery sets Sensor specifications and its components Operating and servicing rules There is the information about tare packaging and conditions of the sensor transportation This document contains the required information for the correct operation maintenance and storage of the sensor The manufacturer constantly improves the sensor and reserves the right t...

Page 4: ... of 12 sub zones Each sub zone can be adjusted using a PC via USB interface disconnection of sub zones separately sensitivity setting in each sub zone and etc remotely via the interface RS 485 or with an Android Device via the wireless interface Bluetooth 3 SPECIFICATIONS 3 1 The operation frequencies range is 24 05 24 25 GHz 3 2 The maximum detection zone length is 30 m 12 cross cut subzones of 2...

Page 5: ...up to 15 sec 3 9 The sensor power supply from 10 up to 30 VDC with the maximum pulsation of 0 03 V The maximum power consumption is 1 5 W 3 10 The sensor has the automatic and remote control 3 11 The sensor doesn t generate an alarm at rain snow fog solar radiation wind speed up to 20 m sec birds and small animals in the detection zone with the linear dimensions up to 0 3 m irregularities up to 0 ...

Page 6: ...ransceiver unit radiates electromagnetic oscillations in the direction of the protected area The electromagnetic oscillations are reflected from the goal and surrounding objects and get to the super high frequency receiver of the transceiver unit When an intruder moves in the detection zone the changes in the received signal caused by the Doppler Effect are intensified and processed according to t...

Page 7: ... provides the unit turn on horizontal plane for 360 º on vertical plane up 15º minimum down 40º minimum 6 3 The transceiver unit is mounted on a vertical plane wall fence etc with the bracket bracket 2 as shown in fig 6 2 or 6 3 The rotation angles on the bracket on a horizontal plane are 180º on a vertical plane up 17º down 45º There are 3 types of the bracket indented from a wall at the distance...

Page 8: ...it our internet sites www forteza com or www forteza eu Page 8 1 support 1 pc 8 cable 1 pc 2 bracket 1 pc 9 bolt M6x35 1 pc 3 bushing 1 pc 10 nut M6 1 pc 4 base 1 pc 11 washer 6 2 pcs 5 case 1 pc 12 bolt M6x35 1 pc 6 cover 1 pc 13 buckle 2 pcs ...

Page 9: ...c 3 figured washer 2 pcs 9 nut М6 2 pcs 4 bracket fastener 1 pc 10 washer 6 4 pcs 5 Rx 1 pc 11 bolt М6х14 1 pc 6 screw М6х50 4 pcs Fig 6 2 Mounting on a wall using BRACKET 350 or BRACKET 500 Note Dear user Manufacturer of the sensor FM 30 24 constantly upgrades its quality and reliability That s why in some lots of sensors there can be design modifications unspecified in the documents delivered wi...

Page 10: ... the sensor outdoor Fasten the visor on the case of the sensor with two screws 3 9x19 containing in the delivery kit as shown in Fig 6 1 The input cable should be threaded through the corrugated pipe If you use a junction box insert a cable gland in it and connect the corrugated pipe to the cable gland The protected site should meet the following requirements a height of irregularities should not ...

Page 11: ...regions the support superstructure should be up to 1300 mm If the sensor is used to block the upper part of the fence it is recommended to weld or to gear together the support and the fence for firmness In this case the support should be situated above the fence at 300 mm minimum 8 3 2 Lay the main cables according to the project of the security system It is recommended to use cables with the core...

Page 12: ...FORTEZA JSC FORTEZA FM 30 24 BT Please visit our internet sites www forteza com or www forteza eu Page 12 Fig 8 1 Detection zone parameters of the modification Volume at the height of 1 m ...

Page 13: ...lease visit our internet sites www forteza com or www forteza eu Page 13 Fig 8 2 Detection zone parameters of the modification Curtain at the height of 1 m Fig 8 3 Detection zone parameters of the modification Fan at the height of 1 m ...

Page 14: ...he marking in the chosen place as shown in fig 6 2 Fix bracket 2 with screws 6 on wall 1 3 types of the bracket indented from a wall at the distance of 120 mm 350 mm and 500 mm Insert the bolt 11 in the slot of ring 8 and fasten the transceiver unit on bracket 2 Loosen nut 9 and point the unit on the necessary direction turning it in a horizontal surface Tighten nut 9 Moving the transceiver in a v...

Page 15: ...lay contacts pink purple Tamper circuit TAMPER black green Remote control RC blue RS 485 B red RS 485 A grey Bluetooth activation To activate the Remote Control energize the green RC wire of the output cable with voltage from 10 up to 30 VDC for 1 sec The scheme of the sensor connection using the lightning guard unit LGU 4 and the power supply unit PSU U 15 0 15 is shown in fig 9 1 ...

Page 16: ... 16 Fig 9 1 Connection diagram using LGU 4 The micro switch positions and the detection zone length are given in Table 9 2 Table 9 2 Subzone number Subzone range from the sensor 1 0 2 5 m 2 2 5 5 m 3 5 7 5 m 4 7 5 10 m 5 10 12 5 m 6 12 5 15 m 7 15 17 5 m 8 17 5 20 m 9 20 22 5 m 10 22 5 25 m 11 25 27 5 m ...

Page 17: ...ion 10 ADJUSTMENT WITH A PC 10 1 The sensor can be adjusted with a PC It provides an opportunity to form a complex detection zone set complex sensitivity and visually assess the level of noise and signal The sensor connection with a PC is realized with standard connective cable USB A USB B To control the sensor with a computer it is necessary to set up the software which includes 2 stages virtual ...

Page 18: ...FORTEZA JSC FORTEZA FM 30 24 BT Please visit our internet sites www forteza com or www forteza eu Page 18 Fig 10 1 Fig 10 2 Choose the folder COM PORT in window of Search and Installation Options ...

Page 19: ...FORTEZA JSC FORTEZA FM 30 24 BT Please visit our internet sites www forteza com or www forteza eu Page 19 Fig 10 3 Fig 10 4 Click Finish and the sensor is ready for use ...

Page 20: ...y to know its number Please follow START OPTIONS CONTROL PANEL SYSTEM DEVICE DEVICES MANAGER PORT COM and LPT USB SERIAL PORT and remember the number 10 3 Sensor Control Program installation To install the program please start ConfigMaster_setup exe After the file ConfigMaster_setup exe has been started it will appear the following window Fig 10 5 ...

Page 21: ...FORTEZA JSC FORTEZA FM 30 24 BT Please visit our internet sites www forteza com or www forteza eu Page 21 Install the program following the instructions Fig 10 6 Fig 10 7 ...

Page 22: ...FORTEZA JSC FORTEZA FM 30 24 BT Please visit our internet sites www forteza com or www forteza eu Page 22 Fig 10 8 The installation of ConfigMaster is finished ...

Page 23: ...t Run the program in the name of Administrator 10 4 Computer controlled operation Connect the sensor to the computer with the USB cable and apply power to the sensor From the desktop run the program ConfigMaster After the program has been started it will appear the window shown in Fig 10 9 Fig 10 9 If the manual search is selected the window shown in Figure 10 10 will appear where you must specify...

Page 24: ...selected the search starts immediately If the search fails check the power supply and connect the detector to the PC If the sensor is found it begins automatically the data exchange between the sensor and PC The indicator Status changes from gray to green and the active window becomes like shown in Fig 10 11 If the Exchange status becomes red it means no exchange between the sensor and PC In this ...

Page 25: ... and noise level in every sub zone and the sensor is managed with built in control devices This mode let control the sensors settings and its operation visually To control the sensor from the computer tick PC Control in the program window The program window changes like shown in Fig 10 12 Managed by PC you can make a complex detection zone approved passages sensitivity in every subzone noises cont...

Page 26: ...eration Settings the button Save to Memory and Return to the factory settings You also can switch ON or OFF the subzones The button Save to memory saves all changes in the permanent memory and Return to the factory settings brings the thresholds value and signal gain to 50 The field Logic number shows the number of the sensor connected to the computer In the mode Settings you can set up the signal...

Page 27: ...ensor and version of the software You can change the logic number address of the sensor if you need Click the right mouse button in the main program window and choose the menu option Change the logic address After you have done it it will appear a window shown in Fig 10 14 If you enter a new logic number and click OK it will be given the sensor number and the program stores this number Program res...

Page 28: ...ch subzone The signal level in each subzone is in green color By threshold crossing the color of signal becomes red The factory threshold settings make up 50 of the full scale A signal in the subzones with no objects in the detection zone shows a noise level The reason of noises can be high vegetation and other moving objects or a powerful electromagnetic radiation source and also mutual influence...

Page 29: ...to make at the full height or bent over with the minimal and maximal speed 0 3 8 m s At the final stage please set the approved passages switching off subzones 4 and 5 A sample of such configuration is given in Fig 10 15 Fig 10 15 Doing the control passages check the detection zone configuration When the checking and adjustment are over click Save to Memory to save the configuration in the nonvola...

Page 30: ...t the Software installation is finished 2 Download the APK file from the website htpp forteza eu com To install the program please record the APK file FM UNI to the Android device and start it After the file would be started please press the button Install and wait till installation will be finished Press the button Done After that the installation of the program is complete The program is univers...

Page 31: ...wired via USB and wireless via Bluetooth 11 3 Connection via USB The mobile device should have an OTG slot Power the sensor take off the back slot cover and connect the USB cable to the slot To the other end of the USB cable please connect the OTG cable Figure 11 2 Fig 11 2 Connect the MicroUSB cable to the mobile device and choose the connection way USB It will open the following program window F...

Page 32: ...SC FORTEZA FM 30 24 BT Please visit our internet sites www forteza com or www forteza eu Page 32 Fig 11 3 Press the button Connect and it will appear the access permission to the USB device Figure 11 4 Fig 11 4 ...

Page 33: ...Connect will change into Start the data exchange Figure 11 5 Fig 11 5 Press the button Start the data exchange and the program will run Go to the item 11 5 11 4 Connection via Bluetooth Power the sensor and connect the grey cable Bluetooth to the contact power supply Bluetooth is active only with connection to power supply and choose the connection way Bluetooth Bluetooth on the Android device wil...

Page 34: ...ch and the automatically search starts Figure 11 7 Fig 11 7 Upon search completion please choose a device from the list by click Figure 11 8 Fig 11 8 It will open the work window If no devices were found please check the power of the sensor and connection of the Bluetooth cable Press the button Start the data exchange and the program will run ...

Page 35: ...g 11 9 Fig 11 9 The program window displays the signal levels and interferences in the subzones and the switches Operation and Settings The signal level in each sub zone is displayed in a green column that varies in height when the threshold is exceeded the signal bar turns to red The threshold is indicated by a green runner on the columns of the subzones and numerically above them ...

Page 36: ...gical Number field is used to display and switch the logical number of the sensor To change the logical number simply select a new logical number from the list Figure 11 10 After the logical number would be changed it appears the text The logical number has been changed Fig 11 10 To set the sensitivity please tick a cell in the field Settings The work window of the program is given on fig 11 11 ...

Page 37: ...rator makes control passages in the second half of every subzone and the second one achieves a sure alarm generating with special regulators while the signal level should be approximately the same in all subzones and be 90 10 of the height of the column The control passages should be done at full height and bent over with a minimum and maximum speed 0 3 8 m s After adjusting the sensitivity the le...

Page 38: ...check the appearance of the site meeting the requirements given in item 8 1 12 2 2 Every three months take measures are required every month check the cable and cable splices check fasteners of the brackets 12 2 3 During seasonal works control the height of grass In case the grass is higher than 0 3 m it is necessary to remove it In case of change of height of snow cover on the site false alarms c...

Page 39: ...ensor 3 The protected area doesn t meet the necessary requirements Inspect the protected area according to the requirements of the issue 8 and remove the defects 4 The transmitter receiver unit is out of order Replace the transmitter receiver unit 2 False alarms 1 Moving objects in the detection zone Inspect the sector and remove interference factors 2 Animals movement in the sector 3 Too high sen...

Page 40: ...l in the case of jolts 16 ACCEPTANCE CERTIFICATE The security sensor FM 30 24 __ BT __________________ meets the performance specifications of the Document Part Number 4372 062 43071246 2011 and is considered as operable Date of issue _________20___ Quality department 17 MANUFACTURER S WARRANTIES 17 1 The manufacturer guarantees the conformity of the sensor specifications to the Document Part Numb...

Page 41: ...e 53 11 13 69 С Longitude 45 12 18 51 В Postal address 442960 Russia Zarechny Penza region P O box 45 Tel 7 8412 655316 Fax 7 8412 655317 E mail info forteza eu com Website www FORTEZA EU com Manufacturer in Europe JSC Forteza Postal address Tilzes str 38 LT 91112 Klaipeda Lithuania Contacts Tel 37046411353 multichannel Fax 37046412231 E mail forteza forteza com The detailed information you can fi...

Reviews: