7.1.12 Physical Reset
A user can load the configuration of the switch to factory defaults using a port loop-back. This also loads the
factory default IP configuration. This option may be required if the switch IP address is not known and/or the
switch is not communicating over the network. The new configuration is available immediately. The following
procedure shows the steps for resetting the factory defaults using loop-back:
a. Loopback between Port-1 & Port-2 of the main switch using standard Ethernet cable
b. Power on the board and wait till the Ethernet connection is established
c. Remove the loopback cable
Note: The factory default configuration is only loaded and not stored. To permanently store this configuration,
refer to section 7.1.9.