Epsilon-8100 User Manual Revision A.3
www.diamondsystems.com
Page 30
7.1.8 Web Interface Activation / Deactivation
The web interface can be activated and deactivated through either the command line interface or the web Control
Panel.
Using the Control Panel, in the Configuration/Security/Switch/Access Management Configuration screen, first
ensure the mode is set to Disabled as shown below. This is the default mode. If it is not set to Disabled, set it as
Disabled and click Save.
This configuration should be stored on the switch with the following CLI command:
#copy startup-config flash:{filename}
To disable web access of the switch, in the Control Panel navigate to the Configuration/Security/Switch/Access
Management Configuration screen, change the mode to Enabled and click Save.
Now there is no access to the switch using the web interface. To store this configuration in flash as the standard
configuration on startup, enter the following command in the CLI:
#copy running-config startup-config
To allow web access of the switch in the future, enter the following commands in the CLI:
#copy startup-config flash:backup_config
#copy flash:{filename} startup-config
Then reboot the switch.
7.1.9 Firmware Upgrade
The following section shows the steps necessary to upgrade the firmware:
1. Connect to the web interface of EPS-8100 switch and navigate to Maintenance -> Software -> Upload
(as shown in the figure below)
2. Choose Epsilon-8100.dat file and click on upload
The existing firmware is erased and new firmware loaded. Once the upgrade completes the switch reboots
automatically.
Figure 12
–
Firmware Upgrade