background image

 

 

 

The information contained in this document has been carefully researched and is, to the best 
of  our  knowledge,  accurate.  However,  we  assume  no  liability  for  any  product  failures  or 
damages,  immediate  or  consequential,  resulting  from  the  use  of  the  information  provided 
herein. Our products are not intended for use in systems in which failures of product could 
result  in  personal  injury.  All  trademarks  mentioned  herein  are  property  of  their  respective 
owners. All specifications are subject to change without notice. 

 
 

 

 

 

 

 

Manual 

Epsilon-8100 

Diamond Systems 

 

 

 
 
 
 

Our company network supports you worldwide with offices in Germany, Austria,  

Switzerland, Great Britain and the USA. For more information please contact:

 

 
 

 

FORTEC Elektronik AG

 

Hauptniederlassung 
Lechwiesenstr. 9 
86899 Landsberg am Lech 
 
Telefon:   +49 (0) 8191 91172-0 
Telefax:   +49 (0) 8191 21770 
E-Mail:  

[email protected]

 

Internet:    

www.fortecag.de

 

FORTEC Elektronik AG

  

Büro West 
Hohenstaufenring 55 
50674 Köln 
 
Telefon:   +49 (0) 221 272 273-0 
Telefax:   +49 (0) 221 272 273-10 
E-Mail:  

[email protected]

 

Internet:  

www.fortecag.de

 

 

 
FORTEC Elektronik AG 

Büro Wien 
Nuschinggasse 12  
A-1230 Wien 
 
Telefon:   +43 1 8673492-0  
Telefax:   +43 1 8673492-26  
E-Mail:  

[email protected]

 

Internet:  

www.fortec.at

 

 
ALTRAC AG

  

(Tochter der FORTEC):  
Bahnhofstraße 3 
CH-5436 Würenlos 
 
Telefon:   +41 (0) 44 7446111  
Telefax:   +41 (0) 44 7446161  
E-Mail: 

[email protected]

 

Internet:  

www.altrac.ch

 

 

 

Summary of Contents for Epsilon-8100

Page 1: ...ou worldwide with offices in Germany Austria Switzerland Great Britain and the USA For more information please contact FORTEC Elektronik AG Hauptniederlassung Lechwiesenstr 9 86899 Landsberg am Lech T...

Page 2: ...014 Initial Release A 1 1 23 2015 Removed POE information A 3 1 4 2016 Minor updates Copyright 2016 FOR TECHNICAL SUPPORT Diamond Systems Corporation PLEASE CONTACT 555 Ellis Street Mountain View CA 9...

Page 3: ...C Commands 14 6 5 3 VLAN PVLAN Commands 14 6 5 4 dot1x IEEE Standard for port based Network Access Control 15 6 5 5 LACP Commands 15 6 5 6 LLDP Commands 15 6 5 7 Access Management Commands 15 6 5 8 Ac...

Page 4: ...3 7 1 2 Port Configuration 24 7 1 3 Change Password 25 7 1 4 Set up VLANs 26 7 1 5 SNMP Configuration 27 7 1 6 Mirroring 28 7 1 7 Setup QoS 29 7 1 8 Web Interface Activation Deactivation 30 7 1 9 Firm...

Page 5: ...age power supply problems described below To avoid this type of failure only perform assembly operations when the system is powered off Sometimes boards are stored in racks with slots that grip the ed...

Page 6: ...peration of 40 C to 85 C is tested and guaranteed Epsilon 8100 was designed with harsh applications in mind Latching connectors provide increased reliability Software Support The switch is ready to pl...

Page 7: ...Port Gigabit Ethernet Switch with heatspreader PC 104 form factor 40 C to 85 C operating temperature EPS 8100 8 Port Gigabit Ethernet Switch with heatsink PC 104 form factor 40 C to 85 C operating te...

Page 8: ...o connection to a single board computer in the stack Epsilon 8100 is a Layer 2 managed Ethernet switch with built in microcontroller and memory for configuration and management The Flash memory holds...

Page 9: ...ems com Page 8 3 2 Board Layout The following photo shows the locations for all connectors and jumpers which are described in the next sections Figure 2 Epsilon 8100 Connectors and Jumpers LAN1 LAN3 L...

Page 10: ...n greater detail in Section 6 of this document Other connectors and jumper blocks on Epsilon 8100 are reserved for Diamond s use only Connector Function LAN1 8 Ethernet x8 RS 232 RS 232 Serial Interfa...

Page 11: ...eader with tin plating Mating Connector JST Sales America PUDP 10V S housing with SPUD 002T P0 5 terminals 5 2 Serial Interface J12 Epsilon 8100 contains an RS 232 connector J12 which connects the on...

Page 12: ...rd voltage the current will be cut in half If the external LED has a lower forward voltage it will dominate the on board LED and be brighter Therefore if the external LED is not bright enough use an e...

Page 13: ...d at that address The IP address mask and gateway must be set according to your environment or you can enable IP and DHCP if your environment includes a DHCP server For example configure terminal conf...

Page 14: ...vertical arrow keys and to scroll through a command history buffer of the latest 20 commands issued 6 5 General Command Groups The following groups of general commands are available in the command li...

Page 15: ...erface brief show ip route show ip statistics system interface vlan v_vlan_list icmp icmp msg type 6 5 2 MAC Commands config mac address table aging time v_0_10_to_1000000 config mac address table sta...

Page 16: ...tics system id neighbour 6 5 6 LLDP Commands config lldp holdtime val config lldp reinit val config lldp timer val config lldp transmission delay val config no lldp holdtime config no lldp reinit conf...

Page 17: ...active interface port_type v_port_type_list detailed interface port_type v_port_type_list_1 mst configuration instance interface port_type v_port_type_list_2 6 5 11 Green Ethernet Commands config gre...

Page 18: ...server host conf_name config snmp server location v_line255 config snmp server security to group model v1 v2c v3 name security_name group group_name config snmp server trap config snmp server user us...

Page 19: ...port acct_port config no radius server key config no radius server retransmit config no radius server timeout show radius server statistics show running config all defaults show running config feature...

Page 20: ...sword none config password unencrypted password config enable password level priv password config enable secret 0 5 level priv password config no enable password level priv config no enable secret 0 5...

Page 21: ...interface brief Vlan Address Method Status 1 192 168 1 60 Manual UP 6 6 2 Port Configuration Individual ports can be configured to different speed Following example shows configuring speed as 100 Mbps...

Page 22: ...if switchport access vlan 2 config exit config interface GigabitEthernet 1 3 Config if switchport mode access Config if switchport access vlan 3 config exit To verify created VLAN show vlan VLAN Name...

Page 23: ...me Relay Asynchronous Transfer Mode ATM Ethernet and 802 1 networks SONET and IP routed networks that may use any or all of these underlying technologies Following example shows setting up the QoS all...

Page 24: ...d VLAN Configure aggregation groups Configure LACP parameters Configure QoS Configure SNMP Mirroring Read and clear statistics counters Monitor LACP status Configure and monitor 802 1X Configure and m...

Page 25: ...partner and selects the highest speed that is compatible with the link partner c 10 Mbps HDX Forces the cu port in 10Mbps half duplex mode d 10 Mbps FDX Forces the cu port in 10Mbps full duplex mode...

Page 26: ...anged as follows 1 Connect to the web interface of EPS 8100 switch 2 Navigate to Configuration Security Password 3 Enter the Old password and New Password and click on Save refer to figure below 4 Nav...

Page 27: ...p down list c Assign a ports to the virtual LANs by changing the values in the Port VLAN column refer to figure below d Click on Save to save the VLAN configuration e To save VLAN settings permanently...

Page 28: ...terface of EPS 8100 switch 2 Navigate to Security Switch SNMP System and Enable the Mode and set the SNMP version example SNMP v1 SNMP v2c SNMP v2c The following procedure shows the SNMP Trap configur...

Page 29: ...roring For debugging network problems or monitoring network traffic the switch system can be configured to mirror frame from multiple ports to a mirror port The following example shows Mirror traffic...

Page 30: ...this port are mirrored on the mirror port Frames received are not mirrored 3 Disabled Neither frames transmitted nor frames received are mirrored 4 Enabled Frames received and frames transmitted are...

Page 31: ...Access Management Configuration screen change the mode to Enabled and click Save Now there is no access to the switch using the web interface To store this configuration in flash as the standard conf...

Page 32: ...Configuration Save Startup Config refer to the figure below 3 Click on Save Configuration Figure 13 Saving Startup Configuration 7 1 11 Factory Defaults A user can reset the configuration of the switc...

Page 33: ...or the switch is not communicating over the network The new configuration is available immediately The following procedure shows the steps for resetting the factory defaults using loop back a Loopback...

Page 34: ...nk aggregation IEEE 802 3ad RSTP Rapid spanning tree protocol IEEE 802 1W and MTSP Security Advanced security and prioritization available through multistage TCAM engine Power management ActiPHY and P...

Page 35: ...ins definitions and information regarding the properties of managed resources and the services that the agents support The following MIBs are supported by Epsilon 8100 LLDP RFC1213 Interfaces RFC1213...

Page 36: ...ww fortecag de FORTEC Elektronik AG B ro West Hohenstaufenring 55 50674 K ln Telefon 49 0 221 272 273 0 Telefax 49 0 221 272 273 10 E Mail west fortecag de Internet www fortecag de FORTEC Elektronik A...

Reviews: