22
Maximum vacuum current draw
Required circuit amperage
<6 A (230 VAC)
<12 A (120 VAC)
7.5 A (230 VAC)
15 A (120 VAC)
≥6 A (230 VAC)
≥12 A (120 VAC)
10 A (230 VAC)
20 A (120 VAC)
For remotely monitoring the Fuse Sift, ensure that the machine maintains a constant
connection to a secured network. Refer to section
4.6 Setting up a network connection
for
more information.
4.3
Unboxing the machine
For detailed guidance and visual assistance, visit s
upport.formlabs.com
.
Prior to unboxing, ensure that the suitable workspace has been prepared according to section
4.1 Location and environs
.
The Fuse Sift is a heavy object. A two person lift is required to prevent injury and
avoid damage to the machine.
4.3.1
Receiving
The standard Fuse Sift package ships on one pallet and contains the Fuse Sift powder
recovery station, surface grate, and parts basket. Powder cartridges and accessory boxes
ship separately from the Fuse Sift’s packaging.
Depending on the package you purchase, the accessories may ship together on a pallet. If
you are in a building with palletized deliveries, ensure you have access to the loading dock.
Powder recovery
station
Vacuum
Pallet including
product and boxes
(if applicable)
Shipping dimensions
99 × 57 × 156 cm
39 × 22.4 × 61.4 in
50 × 50 × 80 cm
19.7 × 19.7 × 31.5 in
111 × 71 × 178 cm
44 × 28 × 70.1 in
Shipping weight
138 kg
304.2 lb
44 kg
97 lb
154 kg
340 lb
Product weight
93 kg
205 lb
25 kg
55 lb
n/a
4.3.2
Unboxing
The custom packaging the powder recovery station arrives in is specially designed to
protect the machine during shipping. During unboxing, inspect the product for any damage
or missing items. In the case of damage or missing items, contact
or a
.
Removing the machine from its packaging requires at least two people that are
comfortable lifting large and heavy objects.
CAUTION
NOTICE
CAUTION