20
3.4.1
Fire
Do not use water to extinguish an electrical fire. Dousing an electrical fire with water
increases the risk of electrocution, and may cause the fire to spread by allowing
electricity to conduct across additional flammable surfaces.
If a localized fire develops near the Fuse Sift, e.g., inside or outside the Fuse 1, immediately
take the following actions.
If the fire is inside the print enclosure:
1. Immediately disconnect the printer from its power source.
2. Open the filter door and locate the emergency chamber door release cable. Pull the cable
away from the printer until the print enclosure door unlocks.
3. Use an ABC fire extinguisher to cover the affected area generously.
If the fire is too large to control:
1. Immediately leave the area and close the door of the room behind you.
2. Evacuate the building according to your organization’s emergency protocols.
3. Call emergency services once you have reached a safe distance from the fire.
3.4.2
Powder
In an emergency involving powder, always refer to the safety data sheet (SDS) and/or
seek help from a medical professional.
DANGER
WARNING