21
Chapter 1 Before Operation
Editing screen
[4]
[5]
[6]
[7]
[8]
[1]
[2]
[3]
[9]
[10]
No.
Name
Function
[1]
Saved data number display
Displays the number of the data being edited.
When data is newly created, [00] is displayed.
[2]
Paper length
Displays the currently set paper length.
[3]
Folding form outline display
Displays a rough shape of the folding form.
[4]
Folding A setting
Displays currently set folding A length.
When the key is touched, the [Edit] screen of folding A is displayed.
Setting range: 42.0 to *** mm/ 1.65 to *** inch
***: 325.0 mm/12.80 inches or "Paper 5.0 mm/+0.197 inch",
whichever is shorter.
[5]
Folding B setting
Displays the currently set folding B length.
When the key is touched, the [Edit] screen of folding B is displayed.
When folding B is not used, set as 0.0 mm.
Setting range: 0.0/47.0 to *** mm/ 1.85 to *** inches
***: 217.0 mm/8.54 inches or "paper 5.0 mm/+0.197 inch",
whichever is shorter.
[6]
(Folding mode selection)
key
When the key is touched, the [Folding Mode] screen is displayed.
When folding mode is set, value of the folding A and folding B is input
automatically according to the paper size and folding form, and display
returns to this screen.
[7]
Finishing size
Displays the estimated value of the finishing length based on the input
value and folding form.
[8]
(Cancel) key
When you enter this screen from the [Basic Settings] screen, the display
returns to the [Paper Length] input screen. In this case, the values of folding
A and folding B that you have input are temporarily saved, and the values
are restored when you save the paper length.
When you touch the
key on the [Paper Length] input screen,
however, the temporarily stored values are discarded.
Press and hold to return to the [Ready] screen.
[9]
(Save) key
Saves the input value and displays the [Save] screen.
When the combination of input values is in the following conditions, the
data becomes invalid and cannot be saved.
- The value of folding A is set to [0].
- Folding A is larger than L (the paper length).
- Folding B is larger than both folding A and "L - folding A".