![Formax FD 3300 Operation Manual Download Page 24](http://html1.mh-extra.com/html/formax/fd-3300/fd-3300_operation-manual_2320110024.webp)
18
Chapter 1 Before Operation
5-7. [Fold Position] screen
[11]
[12]
[8]
[9]
[10]
[2]
[3]
[4]
[5]
[7]
[11]
[12]
[8]
[10]
[2]
[1]
[3]
[4]
[5]
[6]
[7]
Standard fold/standard folding of non-standard paper
Custom folding
No.
Name
Function
[1]
Folding A reversal
Reverses [+] and [-] of folding dimension A.
When the value after being reversed is outside the specification range, it is
corrected to the nearest value within the specification range.
When in custom folding or stopper fixed mode, it is not displayed.
[2]
Folding A position adjustment
value/Folding dimension A
position (*)
Standard folding: The folding A position adjustment value is displayed.
Custom folding: The folding dimension A is displayed.
When you touch the key, the numeric keypad is displayed, which enables
you to input values.
[3]
Folding A position adjustment
key (*)
Adjusts the position of the folding stopper of the folding plate 1.
[+] Raises the position of folding A. When pressed and held, the value
continues to increase automatically within the setting range.
[-] Lowers the position of folding A. When pressed and held, the value
continues to decrease automatically within the setting range.
[4]
Folding B position adjustment
value/Folding dimension B
position (*)
Standard folding: The folding B position adjustment value is displayed.
Custom folding: The folding dimension B is displayed.
When you touch the key, the numeric keypad is displayed, which enables
you to input values.
[5]
Folding B position adjustment
key (*)
Adjusts the position of the folding stopper of the folding plate 2.
[+] Raises the position of folding B. When pressed and held, the value
continues to increase automatically within the setting range.
[-] Lowers the position of folding B. When pressed and held, the value
continues to decrease automatically within the setting range.
[6]
Folding B reversal
Reverses [+] and [-] of the folding dimension B.
When the value after being reversed is outside the specification range, it is
corrected to the nearest value within the specification range.
When in custom folding or stopper fixed mode, it is not displayed.
[7]
(Test) key
Performs test fold before saving the adjusted value of the folding stopper
position.
[8]
(Return) key
Saves the input value and returns to the [Ready] screen.
When you touch the key while the input value is outside the specification
range, the value within the range that you can input is displayed in "outline
of folding dimension.”