95
diagnostic codes
DTC
How Set
Code Description
Brief Description
Software Parameters
Required to Set Code
Service Instructions /
Part Replaced
O R C
P0402
X
Exhaust Gas Recirculation
Flow Excessive Detected
This error occurs when the estimated EGR percent is greater
than the maximum limit for the operating condition.
DPF regeneration not requested
PTO not active
Pressure ratio across EGR valve < 1
rate of change of engine speed < 0.05
rate of change of indicated
torque setpoint < 0.05
600 rpm <engine speed< 800 rpm
45Nm <tqi_sp< 174Nm
12 sec to run test
2 low flow failures required to set
fault (test runs 5 times per trip)
60 sec wait time between tests
EGR system error
P0403
X
Exhaust Gas Recirculation
Control Circuit
This error occurs when the current through the EGR
control circuit is outside of a predetermined range.
Internal to the engine control module
Wiring, EGR valve
assembly, PCM
P0404
X
Exhaust Gas Recirculation
Control Circuit Range/
Performance
This error is set when the deviation in EGR
position is outside the threshold.
10 percent of full range error >5 sec
System error, EGR valve, PCM
P0405
X
X
X
Exhaust Gas Recirculation
Sensor A Circuit Low
This error occurs when the EGR position voltage is below the
specified voltage for a predetermined amount of time. This
error can indicate either a short to ground or an open circuit.
0.24v <3 sec
Wiring, EGR valve
assembley, PCM
P0406
X
X
X
Exhaust Gas Recirculation
Sensor A Circuit High
This error occurs when the EGR position voltage is
above the specified voltage, for maximum position given
the current operation, for a predetermined amount of
time. This error can indicate a short to power.
4.84v <3 sec
Wiring, EGR valve
assembley, PCM
P041B
X
X
X
Exhaust Gas Recirculation
Temperature Sensor B
Circuit Range/Performance
This error occurs when the change in the EGR
cooler outlet temperature is less than the threshold
for a predetermined period of time.
Initial ECT < 30 deg C
ECT increase to > 80 deg
C during drive cycle
ECM on time > 3 seconds
TEGR_IN has not changed more
than 6 deg. C in 2 drive cycles
Wiring, Tegr_OUT sensor, PCM
P041C
X
X
X
Exhaust Gas Recirculation
Temperature Sensor
B Circuit Low
This error occurs when the EGR cooler outlet sensor
temperature output value is lower than a minimum
probable temperature for a predetermined amount of
time, indicating an open circuit or short to power.
0.15v > 5sec.
Wiring, Tegr_OUT sensor, PCM
P041D
X
X
X
Exhaust Gas Recirculation
Temperature Sensor
B Circuit High
This error occurs when the EGR cooler outlet
sensor temperature output value is higher than a
maximum probable temperature for a predetermined
period of time, indicating a short to ground.
N > 650 rpm
torque setpoint >53 N-m
ECT > 60 deg C
4.95v > 5 sec
Wiring, Tegr_OUT sensor, PCM
P0420
REGEN
Catalyst System Efficiency
Below Threshold
This error occurs if the observed exothermic reaction (a
reaction that produces heat) during a regeneration event
falls below a threshold for a predetermined period of time.
P042E
X
X
X
EGR Control Stuck Open
This error occurs when the EGR set point is less
than a specified threshold, the actual EGR position
is greater than a specified threshold, and the EGR
control limit is less than a specified limit.
EGR Position > 30 %
EGR Position desired < 15% > 4 sec
System error, EGR valve, PCM
P042F
X
X
X
EGR Control Stuck Closed
This error occurs when the EGR set point is greater
than a specified threshold, the actual EGR position
is less than a specified threshold, and the EGR
control limit is greater than a specified limit.
EGR Position < 15 %
EGR Position desired > 30% > 4 sec
System error, EGR valve, PCM
P0472
X
Exhaust Pressure Sensor
A Circuit Low
This error occurs when the EP signal voltage is lower than
a specified value for a predetermined period of time.
0.15v < 3 sec
Wiring, EP sensor, PCM
P0473
X
Exhaust Pressure Sensor
A Circuit High
This error occurs when the EP signal voltage is higher than
a specified value for a predetermined amount of time.
4.90v < 3 sec
Wiring, EP sensor, PCM
P0480
X
Fan 1 Control Circuit
P0488
X
EGR Throttle Position Control
Range/Performance
This error occurs when there is an error in throttle position
vs. desired position, high temperature condition and throttle
not returned to open position when commanded, faulty
input signal detected, or broken return spring detected.
THR_STATE is low > 3 sec
Wiring, EGRTP, PCM
P0494
X
Fan Speed Low
P0495
X
Fan Speed High
P0500
X
Vehicle Speed Sensor A
This error occurs when either a faulty signal or a missing
signal occurs from the vehicle speed sensor circuit.
P0503
X
Vehicle Speed Sensor A
Intermittent/Erratic/High
This error occurs when an intermittent error is
detected in the vehicl speed sensor circuit.
Summary of Contents for 6.4L Power Stroke
Page 3: ... This page intentionally left blank ...
Page 5: ... This page intentionally left blank ...
Page 6: ... 6 4L Power Stroke Diesel Direct Injection Turbocharged Diesel Engine ...
Page 33: ...32 This page intentionally left blank ...
Page 51: ...50 This page intentionally left blank ...
Page 73: ...72 This page intentionally left blank ...
Page 89: ...88 wiring diagram single alt reference only Refer to Ford Wiring Diagrams for Wiring ...
Page 90: ...89 wiring diagram single alt reference only Refer to Ford Wiring Diagrams for Wiring ...