Installation
Centellis CT Series 16000 User’s Manual
Page 8
20000325 420 000 AB
CAUTION
!
ESD PRECAUTIONS - Static Destroys Products
•
The chassis contains static-sensitive devices. Good static control procedures
should be used when installing, removing, and handling all components. Use
an antistatic wrist strap at all times. Never touch the board components with
any conductive objects.
2.3
Pre-Installation Instructions
Upon receipt of your Centellis CT Series 16000 system, check the attached packing slip to verify
that the equipment that was ordered was correctly shipped and received in full. Contact Force
Computers if any discrepancy exists among the original purchase order, the packing slip, and the
received equipment.
Visually inspect the product for any physical damage. The product was shipped from Force Com-
puters manufacturing in working condition; any product damage must be immediately reported to
the shipping agent.
Save the shipping carton and enclosed packing material in case the system must be reshipped in
the future.
2.4
Chassis Front Description
The Centellis chassis is shipped with two 7-slot 6U front panels that cover the 14 user I/O
expansion slots. An installed CPCI-723 module separates the panels into two 7-slot CPCI
segments. Use a small Phillips screwdriver to remove the panels. An installed peripheral tray panel
for a 5.25" drive bay fills the far right end of the chassis. A pluggable fan tray panel with air intake
grillwork is attached to the bottom of the chassis via thumb screws.