34
10. About SNMP
The USF-105AS can be remotely monitored using an SNMP monitoring system that supports
SNMPv2C.
MIB (Management Information Base) files, required for SNMP monitoring system, can be downloaded
from WebGUI. Refer to Sec. 9-4. "SNMP Tab" for details on downloading MIB files and SNMP settings.
GET List
Object group
Item Name
Object name in MIB file
Value
OID
Type
TRAP
Function
OID : 1.3.6.1.4.1.20175.1.349.1.
Unit Status
Product Name
usf105ASProductName
USF-105AS
1
OCTET
STRING
Product Code
usf105ASProductCode
1023867
2
INTEGER
Serial Number
usf105ASSerialNumber
1826****
3
INTEGER
Soft Ver
usf105ASVersion
**.**
4
OCTET
STRING
Power Unit1 Detection
usf105ASPowerUnit1Detection
-1:notInstalled
0:notDetected
1:detected
5
INTEGER
Power Unit1 DC Output
usf105ASPowerUnit1DcStatus
-1:notInstalled
0:normal
1:abnormal
6
INTEGER
Power Unit2 Detection
usf105ASPowerUnit2Detection
-1:notInstalled
0:notDetected
1:detected
8
INTEGER
Power Unit2 DC Output
usf105ASPowerUnit2DcStatus
-1:notInstalled
0:normal
1:abnormal
9
INTEGER
Card Temperature
usf105ASCardTemperature
**degree Celsius
11
INTEGER
Front FAN Status
usf105ASFrontFanStatus
0:normal
1:stopped
fan1Stopped(Bit0)
fan2Stopped(Bit1)
fan3Stopped(Bit2)
fan4Stopped(Bit2)
12
BITS
* No item can be set from SNMP Manager.
Power Unit1 Detection
Obtains the Power Unit 1 status.
detected
: Indicates Power Unit 1 output is normal.
notDetected
: Indicates Power Unit 1 output is not detected.
notInstalled
: Indicates Power Unit 1 is not installed when turned on.
Power Unit1 DC Output
Obtains the Power Unit 1 DC output status.
normal
: Indicates Power Unit 1 DC output is normal.
abnormal
: Indicates Power Unit 1 DC output is abnormal.
notInstalled
: Indicates Power Unit 1 is not installed when turned on.
Power Unit2 Detection
Obtains the Power Unit 2 status.
detected
: Indicates Power Unit 2 output is normal.
notDetected
: Indicates Power Unit 2 output is not detected.
notInstalled
: Indicates Power Unit 2 is not installed at the point of powered on.
Power Unit2 DC Output
Obtains the Power Unit 2 DC status.
normal
: Indicates Power Unit 2 DC output is normal.
abnormal
: Indicates Power Unit 2 DC output is abnormal.
notInstalled
: Indicates Power Unit 2 is not installed when turned on.
Card Temperature
Obtains the Control Module temperature status.
Front FAN Status
Obtains the USF-105AS Front fan status as Bit0 to Bit3. Bit0 to Bit3
indicate FAN1 to FAN4 states respectively. Each bit indicates 0 when the
fan is operating, and indicates 1 when the fan has stopped.