53
Instructions for the installer
3.9.2
DHW
Prior to installing the boiler, the hydraulic system is to be cleaned in order to remove impurities; they could be present in system components
and damage the water heater.
The cold water inlet and the DHW outlet must be connected to the respective 1/2” connectors C and F on the boiler (see Fig. 6 Paper template).
Hardness of water supplied to the boiler may increase the plate heat exchanger cleaning/replacement intervals.
WARNING
Depending on the hardness of the mains water supply, ascertain whether or not to install appropriate domestic water treatment
systems using water treatment products suitable for drinking water and compliant with the regulations and standards in force in
the country of installation.
Water treatment is always advisable when water supplied to the boiler is more than 20°F hard.
Water supplied by commonly marketed water softeners, due to PH level induced in water, may not be compatible with some
components in the system.
WARNING
It is advisable to convey the discharge flow of boiler safety valve to the sewer system. Should the above precaution not be
implemented and the safety valve be activated, boiler room flooding may occur.
The manufacturer shall not be held responsible in case of damage to people, animals, or property due to failure to follow the
above mentioned instructions.
3.9.3
Condensate drain
Comply with condensate drain laws and standards applicable in the country of installation, which are considered herein integrally transcribed.
Unless forbidden, the condensate produced by combustion is to be routed via the condensate drain through a discharge system connected
to the domestic sewer, which due to its basicity, counteracts flue gas condensate acidity. In order to avoid domestic sewer odour to reach the
premises, it is advisable to install an appropriate device between the discharge system and the domestic sewer. The condensate drain system
and the domestic discharge system is to be made of an adequate, condensate-resistant material.
WARNING
The manufacturer shall not be held responsible in case of damage to people, animals, or property due to failure to follow the
above mentioned instructions.
Summary of Contents for ITACA KB 24
Page 42: ...42 Instructions for the installer Fig 6 Paper template ...
Page 79: ...79 ...