44
Relationship between temperature (°C) and nominal resistance (Ohm) of the central heating probe (SR), of the DHW probe (SS) and of the return
probe (SRT).
T (°C)
0
2
4
6
8
0
27203
24979
22959
21122
19451
10
17928
16539
15271
14113
13054
20
12084
11196
10382
9634
8948
30
8317
7736
7202
6709
6254
40
5835
5448
5090
4758
4452
50
4168
3904
3660
3433
3222
60
3026
2844
2674
2516
2369
70
2232
2104
1984
1872
1767
80
1670
1578
1492
1412
1336
90
1266
1199
1137
1079
1023
Table 14 - Relationship between Temperature and Nominal resistance for temperature probes
Key
DK: water pressure switch
fL/TM: flow switch/timer
SS: DHW NTC probe 10K Ohm at 25 °C
B=3435
STR: return NTC probe 10K Ohm at
25 °C B=3435
SR1-SR2: CH NTC probe 10K Ohm at 25 °C
B=3435
Sf: flue gas NTC probe 10K Ohm at 25 °C
B=3435 or thermal fuse
VG: gas valve
P: boiler pump
MDV: electric deviating valve
E: ignition/flame detection electrode
V: brushless fan
0SCHEMOD22: electronic board
CN_A-CN_M: signal/load connectors
X2-X7: ground connectors
TA (PIN 1 and 2): room thermostat (use
a no load contact)
0CREMOTO04 (PIN 3 and 4): OpenTherm
remote control
SEXT (PIN 5 and 6): external NTC probe 10K
Ohm at 25 °C B=3977
SBC: water heater probe, boiler side, NTC 10K
Ohm at 25 °C B=3435
MULTIfUNCTION RELAY 230 Vac 5A
cosfi=1:
PIN 15: phase, normally open
PIN 16: phase, normally closed
PIN 17: neutral