3
©
2019 Focal Point Fires plc.
3.0 APPLIANCE DATA
Weight (kg):
15kg
Dimensions:
H 620 x W 520 x D 148 (mm)
Supply Voltage:
220~240V AC, 50Hz
Fuse Rating:
13 Amp
Heating Elements:
1500W
Lighting:
LED
This fire is fitted with LED’s (Light Emitting Diode) in place of conventional bulbs. LED’s generate the same light levels as
conventional bulbs, but use a fraction of the energy consumed. LED’s are maintenance free and will not require replacing during
the life of the product.
The appliance is supplied with a pre-wired three pin plug (13 Amp fuse rated) and 1.8 metres of electrical cable. It is therefore
necessary for a suitable electrical socket to be located within this distance and be easily accessible. This appliance is designed to
be wall hung, using the wall fixtures/fixings provided. DO NOT recess any part of appliance into the wall. This appliance is
suitable for installation in static holiday/park homes.
2.0 INSTALLATION REQUIREMENTS
• From time to time, check the cord for damage. Never use the appliance if the cord
or any part of the appliance shows signs of damage.
• DO NOT run the mains cable under carpets, rugs etc.
• DO NOT cover or obstruct the heater in any way. Overheating will result if it is
accidentally covered.
• Never immerse the product in water or any other liquids.
• DO NOT use the appliance outdoors.
• Before cleaning the appliance, ensure it is unplugged from the power and that it is
completely cool.
• DO NOT clean the appliance with abrasive chemicals.
• Never use accessories that are not recommended or supplied by the manufacturer. It
could cause danger to the user or damage to the appliance.
• DO NOT insert or allow foreign objects to enter the inlet or outlet vents as this may
result in electric shock, fire or damage to the appliance.
• DO NOT install the fire using an extension cord.
• Unplug from the mains supply if the appliance is not to be used for long periods.
• This product is only suitable for well insulated spaces or occasional use.
1.0 IMPORTANT NOTES - CONTINUES
GB IE
Model
EBONY LED ELECTRIC
Item
Symbol
Value
Unit
Item
Unit
Heat output
Types of heat input, for electric storage local
space heaters only
Nominal
heat output
Pnom
1.5
KW
Manual heat charge control with
integrated thermostat
N/A
Minimum heat
output
(indicative)
Pmin
0.75
KW
Manual heat charge control with
room and/or outdoor temperature
feedback
N/A
Maximum
continuous heat
output
Pmax, c
1.5
KW
Electronic heat charge control with
room and/or outdoor temperature
feedback
N/A