【 5.2 】  Preset Value

【 Parameter Setting 】

: You can set the signal value corresponding to the up, down, 

left and right buttons

【 Operation Instructions 】

: Start and Exit: When the main interface 【 FN 】 is red, 

press the up key 【 RCVK 】 to Start/Exit the preset

【 Up, Down, Left And Right Keys 】

: After starting the preset, the backlight of the 

up, down, left and right keys will turn green, and the key function will also change 

to "output the set value"

【 5.3 】  Signal Conversion

The input signal is converted into an output signal.For example: the input 

frequency signal is converted into a current signal, and the input range is 0-1000hz 

and converted into 4-20mA

【 Parameter Settings 】

:

(1) 

Input upper limit/input lower limit: the amplitude range of the input signal

(2)

 Output upper limit/output lower limit: the amplitude range of the output signal

(3)

 Overrun allowed: For example, 1-5V is converted into 4-20ma.If the user checks 

this option, when the input is oV, the output will follow to OmA.If the user does not 

check it, then the output is 4mA and the output is locked within the set range

(4)

 Automatic operation:After checking this option, the signal conversion will be 

automatically started at the next power-on, and the signal conversion will be 

automatically canceled when the signal conversion is exited

【 Instructions 】

:

【 Start and Exit 】:When the main interface 【 FN 】 is red, press the key 【 CONVRET 】 

to start/exit the signal conversion mode.After startup, the backlight of the up, 

down, left and right keys will turn off and have no function

【 5.4 】  Program Output

The programming output can automatically complete N cycles of signal output 

according to the parameters set by the user.This function is mainly used for the aging 

test of electric valve or pneumatic valve,Or test work such as PLC program 

debugging

Summary of Contents for SG-003A

Page 1: ...Multi functional Signal Generator OPERATING MANUAL SG 003A...

Page 2: ......

Page 3: ...Signal 06 4 6 24V Loop Detection 07 4 Display Signal Description 2 1 Speci cations 01 2 3 Interface Terminal 02 2 2 Function Introduction 01 2 4 Power Charge 03 2 Product Description 5 1 Engineering...

Page 4: ...example the current signal of 4 20mA corresponds to 0 100 that is 4mA corresponds to 0 12mA corresponds to 50 and 20mA corresponds to 100 This range can be modi ed by parameters PAGE Plug the meter i...

Page 5: ...n a certain period of time Modbus Slave FNIRSI SG 003A can communicate with con guration software or PLC via RS485 set the instrument Firmware Upgrade USB emulated U disk for rmware upgrade When the I...

Page 6: ...version mode Button Function Operation Description RUN Light The power on on output is white light IN Input key Used to switch the input signal mode in the main interface When FN red light is on click...

Page 7: ...mode the button blue light at this time the up key single output the down key reset the left key end the output the right key pause continue ON OFF Con rmation button when the main interface Turn on...

Page 8: ...display of input output actual value and engineering quantity Output Open Circuit Detection When the output is turned on if the interface displays open circuit and ashes it means that the output sign...

Page 9: ...tion Operating Instructions For Speed Mode 1 The speed mode is used to calculate the speed of the motor or gear One revolution of the motor or gear produces 1 pulse one minute is 3000 revolutions so 1...

Page 10: ...upply and detect current 2 Loop 2 After activating the independent 24V power supply The IN port outputs 24V voltage between the 24V port and the COM port It does not a ect the detection type of the in...

Page 11: ...ude range of the output signal 3 Overrun allowed For example 1 5V is converted into 4 20ma If the user checks this option when the input is oV the output will follow to OmA If the user does not check...

Page 12: ...ys After starting the programming output mode the backlight of the up down left and right keys will turn blue The functions of the up down left and right buttons will also change that is the top is a...

Page 13: ...res Output Time Set output time 5 7 Communication USB connection Because the USB analog serial port is used for communica tion Note that charging will slow down after checking the USB connection Slave...

Page 14: ...ve position given Valve position feedback This input the port is closed to 24V as the negative pole of the input signal the input and output are performed at the same time PLC Process instrument etc A...

Page 15: ...e indicated by the technical indicator It may cause the instrument to work abnormally or even damage Error in input and output It is normal that there may be errors in input and output Because the inp...

Page 16: ...ignal Generator Brand Model FNIRSI SG 003A Manufacturer Shenzhen FNIRSI Technology Co Ltd Website www fnirsi cn Address Building C Weihuada Industrial Park Dalang Street Longhua District Shenzhen Guan...

Page 17: ...ge 03 is frequency 04 is millivolt 05 is resistance The upper four bits are the type 1 8 represent S B E K R J T N in turn Lower four bit mode 1 is mV 2 is thermocouple 3 is WR thermocouple Enter Tabl...

Page 18: ......

Page 19: ......

Page 20: ...Download Manuals and Firmware Manufacturer Shenzhen FNIRSI Technology Co Ltd Website www fnirsi cn Address Building C Weihuada Industrial Park Dalang Street Longhua District Shenzhen Guangdong China...

Reviews: