background image

��

PAGE

【 Mode switch 】

:When the main interface 【 FN 】 is white.Press 【 OUT 】 to switch 

the display position of output actual loop current value and engineering quantity

【 Activate independent 24V 】

: After this item is checked, the independent 24V 

power supply starts to output from the (24V) port (IN-) port and the (COM) port, and 

is not affected by input and output signal type switching

【 Activate Hold 】:

 After this item is checked, each time the machine is turned on, 

the 24V state will remain in the state of the last turn-on.Otherwise, every time you 

turn on the 24V, you need to turn it on manually

【 4.6 】  24V Loop Detection

Select the 24V label left and right in the OUT signal type interface to enter this 

function state.In this state, displays the output 24V loop current on the main 

interface.Unlimited input signal detection type

(1)Loop 1

: After starting the output, 24V voltage is output between the (OUT) port 

and (COM) port, and the loop current is detected at the same time, and the current 

is displayed in the "output 24V loop" area.This function can be used to test, for 

example, pneumatic control valves or two-wire transmitters, supply them with 24V 

power supply and detect current

(2)Loop 2

: After activating the independent 24V power supply.The (IN-) port 

outputs 24V voltage between the (24V) port and the (COM) port.It does not affect 

the detection type of the input signal by the (IN+) port.In this case, select mA for the 

input signal type.Then the (IN-) port can be combined with the (IN+) port to form a 

24V output,And at the same time detect the current loop.The function is similar to 

the circuit one

(3)

Port (IN-) can be switched to independent 24V power supply function.It outputs 

a single DC24V voltage, which is the (24V) port at this time.(24V) port used with 

(IN+) to test two-wire transmitters

Notice!

①The difference between 24V loop detection and standalone 24V is:24V 

loop detection output signal port to measure feedback current.

②Independent 24V port and output port can form 24V power supply,It 

can also be combined with the input (+) to form a transmitter to supply 

power and measure the feedback current of the transmitter

【 5.1 】  Engineering

When the signal value of analog quantity is used in the industrial field, it is 

generally necessary to convert it into engineering quantity value.Therefore, in the 

input and output settings of each signal, the instrument can set the upper and 

lower limits of its engineering quantity and the upper and lower limits correspond-

ing to the signal value

5

EXTENSIONS

Summary of Contents for SG-003A

Page 1: ...Multi functional Signal Generator OPERATING MANUAL SG 003A...

Page 2: ......

Page 3: ...Signal 06 4 6 24V Loop Detection 07 4 Display Signal Description 2 1 Speci cations 01 2 3 Interface Terminal 02 2 2 Function Introduction 01 2 4 Power Charge 03 2 Product Description 5 1 Engineering...

Page 4: ...example the current signal of 4 20mA corresponds to 0 100 that is 4mA corresponds to 0 12mA corresponds to 50 and 20mA corresponds to 100 This range can be modi ed by parameters PAGE Plug the meter i...

Page 5: ...n a certain period of time Modbus Slave FNIRSI SG 003A can communicate with con guration software or PLC via RS485 set the instrument Firmware Upgrade USB emulated U disk for rmware upgrade When the I...

Page 6: ...version mode Button Function Operation Description RUN Light The power on on output is white light IN Input key Used to switch the input signal mode in the main interface When FN red light is on click...

Page 7: ...mode the button blue light at this time the up key single output the down key reset the left key end the output the right key pause continue ON OFF Con rmation button when the main interface Turn on...

Page 8: ...display of input output actual value and engineering quantity Output Open Circuit Detection When the output is turned on if the interface displays open circuit and ashes it means that the output sign...

Page 9: ...tion Operating Instructions For Speed Mode 1 The speed mode is used to calculate the speed of the motor or gear One revolution of the motor or gear produces 1 pulse one minute is 3000 revolutions so 1...

Page 10: ...upply and detect current 2 Loop 2 After activating the independent 24V power supply The IN port outputs 24V voltage between the 24V port and the COM port It does not a ect the detection type of the in...

Page 11: ...ude range of the output signal 3 Overrun allowed For example 1 5V is converted into 4 20ma If the user checks this option when the input is oV the output will follow to OmA If the user does not check...

Page 12: ...ys After starting the programming output mode the backlight of the up down left and right keys will turn blue The functions of the up down left and right buttons will also change that is the top is a...

Page 13: ...res Output Time Set output time 5 7 Communication USB connection Because the USB analog serial port is used for communica tion Note that charging will slow down after checking the USB connection Slave...

Page 14: ...ve position given Valve position feedback This input the port is closed to 24V as the negative pole of the input signal the input and output are performed at the same time PLC Process instrument etc A...

Page 15: ...e indicated by the technical indicator It may cause the instrument to work abnormally or even damage Error in input and output It is normal that there may be errors in input and output Because the inp...

Page 16: ...ignal Generator Brand Model FNIRSI SG 003A Manufacturer Shenzhen FNIRSI Technology Co Ltd Website www fnirsi cn Address Building C Weihuada Industrial Park Dalang Street Longhua District Shenzhen Guan...

Page 17: ...ge 03 is frequency 04 is millivolt 05 is resistance The upper four bits are the type 1 8 represent S B E K R J T N in turn Lower four bit mode 1 is mV 2 is thermocouple 3 is WR thermocouple Enter Tabl...

Page 18: ......

Page 19: ......

Page 20: ...Download Manuals and Firmware Manufacturer Shenzhen FNIRSI Technology Co Ltd Website www fnirsi cn Address Building C Weihuada Industrial Park Dalang Street Longhua District Shenzhen Guangdong China...

Reviews: