Operating Manual EMGZ 321.EIP
19.10.2017
33
8.5
Description of Output Parameters
Output value 1
Output value 2
LCD:
Output 1
LCD:
Output 2
Use:
This parameter determines the signal that will be outputted to the
analogue outputs and displayed on the LCD. The user can select the
sum or the difference of force sensor A and B or each sensor
individually. With the later choice e.g. the force on the left and right
side of the roller can individually be monitored.
Unit
Parameter Range
Selection
Default
Min
Max
- -
-
Ten.
׀
A-B
׀
Ten. A+B
Ten. A
Ten. B
Output 1=
Ten.
׀
A-B
׀
Output 2=
Ten. A+B
Output Mode Selection
LCD:
Out1Mode
Use:
This parameter selects the output mode. The analogue output 1 can
be set to work as a voltage or as a current output.
Unit
Parameter Range
Selection
Default
Min
Max
- - -
0..10V
0..20mA
4..20mA
+/- 10V
+/-10V
Output Mode Selection
LCD:
Out2Mode
Use:
This parameter selects the output mode.
Unit
Parameter Range
Selection
Default
Min
Max
- - -
0..10V
+/- 10V
0..10V