Operating Manual EMGZ 321.EIP
19.10.2017
37
Limit Condition Relay Output 1
Limit Condition Relay Output 2
LCD:
LimCond1
4)
LCD:
LimCond
4)
Use: The
LimCond1
determines whether the relay output must be activated
when over-shooting (
> Limit
) or under-shooting (
< Limit)
the value
stored in the Parameter
Limit 1
. Analogously this holds for
LimCond2
.
Unit
Parameter Range
Selection
Default
Min
Max
- -
-
< Limit
> Limit
LimCond 1=
< Limit
LimCond 2=
> Limit
Limit 1
Limit 2
LCD:
Limit 1
4)
LCD:
Limit 2
4)
Use:
The relay output will be activated, if the threshold value stored in this
parameter
Limit 1
is exceeded or falls below the value (dependent
from the setting in parameter
LimCond
). Analogously this holds for
Limit 2
Unit
Parameter Range
Selection
Default
Min
Max
N
1)
0.1
200’000.0 -
100.0
1)
The display shows the unit of measure that was previously selected
4)
This parameter is only displayed, if the function check “Limit 1” or “Limit 2” have
been assigned to Relay 1 respectively Relay 2.
5)
A relay function can only be assigned once to a relay output. If a function is being
used the function will not appear on the parameter selection.