Operating Manual EMGZ 321.EIP
19.10.2017
59
12
Technical Specification
12.1
Technical Data
Parameter
Specification
Number of Channel
2 Channel for 2 force sensors @350
Ω
Sensor Supply
5 VDC, max. 60mA, high stability
Input signal range
0 to 9mV (max. 12.5mV)
Resolution A/D converter ±8192 Digit (14 Bit)
Measuring error
<0.05% FS
Processor cycle time
1 ms
EtherNET/IP minium
cycle time
2 ms
Operation
3 buttons, 5 buttons wind rose,
LCD-display 2x8 characters (size 8mm)
Interfaces
EtherNet/IP-Bus; Standard: CIP über IEE 802.3
Power supply
24VDC (18 to 36VDC) / 10W (max. 0.5A)
For EMGZ321ACV: 85 to 264 VAC, 50/60 Hz; max.
120W
Temperature range
-10 to 60°C (14 to 140°F)
Protection class
EMGZ321.R and S: IP50
EMGZ321.W, ACV: IP65
Weight
EMGZ321.R: 0.57kg [1.26 lbs]; EMGZ321.S: 0.40kg
[0.88 lbs]; EMGZ321.W: 0.72kg [1.59 lbs];
12.2
Input / Output Configuration
In / Outputs
Configuration
Analogue input 1
1 sensor with strain gauges @ 350
Ω
(0 to 9 mV, max. 12.5 mV)
Analogue input 2
1 sensor with strain gauges @ 350
Ω
(0 to 9 mV, max. 12.5 mV)
Analogue output 1
0 to 10 VDC; ±10VDC; 0/4 to 20mA)
Analogue output 2
0 to 10VDC¸±10VDC;
Digital Inputs
2 inputs @ 24 VDC galvanically isolated
Relay outputs
2 outputs (DC: 220V/2A/60W; AC:250V/2A/62.5VA)