2.2
List of Safety Instructions
Some contacts on the pc board are supplied with a power of 230V!
Mortal danger! Disconnect the power supply before you open the housing!
Proper function of the FMS web guide is only guaranteed with the recommended
application of the components. In case of other arrangement, heavy malfunction
can be the result.
Local safety regulations and guidelines for the installation of electric equipment
have to be obeyed. They are not taken into consideration in this operating
manual. However, they have to be followed strictly.
Bad electrical grounding may cause electric shocks to persons, malfunction of the
total system or damage of the control unit! It is vital to ensure that proper
grounding is set.
The processor board is mounted directly behind the operation panel. Improper
handling of the electronic boards may cause damage to the fragile equipment!
Don’t use rough tools such as screwdrivers or pliers! Operators handling the
electronic boards must wear a well earthed bracelet in order to discharge static
electricity
Welding on the machine frame or components can cause defect on the electronic
components. Always disconnect the controller from the power supply before
welding.