Operating Manual BKS309.W.M
22.02.2019
23
8
Operating parameters
Adjusting the offset [Ref Pos]
Description:
the is stored as long the controller is connected to the power supply.
Range:
-5.00 to
+5.00
Default: 0.00
Increment
0.01
unit:
[mm]
Origin of the reference value [Ref Mode]
Description:
This parameter allows you to define the origin of the reference value
when you switch to the automatic mode.
Setting: [Manual]
Description:
This setting will take the reference value from the parameter [Ref
Mode] (default).
Setting: Automatic
[Auto]
Description:
this setting will take the current position of the web (in the sensor
area) as reference value.
Note:
The two parameters [RefMode] and [SafeRef] are conditionally
dependent on each other. If you require one of both functions, either
set [RefMode] to [Auto] or [SafeRef] to [Yes] .
Do not activate both functions simultaneously!
Storing changes of the reference value [SafeRef]
Description:
This parameter stores changes of the reference value and restores
them after a restart of the system or sets it to zero.
Setting: [No]
Description:
Sets the reference value to zero after a restart of the system.
(Default)
Setting: [Yes]
Description:
Sets the reference value to the last stored value after a restart of the
system.
Note:
The two parameters [RefMode] and [SafeRef] are conditionally
dependent on each other. If you require one of both functions, either
set [RefMode] to [Auto] or [SafeRef] to [Yes] .
Do not activate both functions simultaneously!
Tolerance range without influence on control [Deadband]
Description:
Control is activated as soon as the deviation between reference
value and actual value increases the value of this parameter. A value
of 0.3 mm makes a dead band of ±0.3 mm without any reaction of
the control.
Range:
0.0 to
2.0
Default:
0.1
Increment
0.1
unit:
[mm]