Operating Manual BKS309.W.M
22.02.2019
29
Actuator position in maximum extended position [Max Pos]
Description:
This parameter determines the position of the actuator in the most
extended position. This position acts as stop and will never be
crossed. Refer to page 17
.
Range:
0.0 to
300.0
Default:
125.0
4)
Increment:
0.1
unit: [ mm]
Requirement:
4)
The default setting is depending on the type (stroke) of the
installed actuator. This parameter is only accessible if an actuator of
the FMS winderGLIDE series is installed.
Alignment of the actuator [Actuator]
Description:
This parameter is important for the control logic and determines the
moving directions of the actuator.
Requirement:
This parameter is only accessible if an actuator of the FMS
winderGLIDE series is installed.
Setting: [Left]
Description:
The actuator is mounted on the left side of the winding/unwinding
station in reference to the moving direction of the web. (Default)
Setting: [Right]
Description:
The actuator is mounted on the left side of the winding/unwinding
station in reference to the moving direction of the web.
Type of traverse [TvTyp L] and [TvTyp R]
Description:
This parameter determines which type of traverse is installed on the
left and right side of the web guide system. Parameters for both
sides are visible although you have only installed one traverse.
Setting:
[TA.200]
Description:
Motorized traverse with a stroke of 200 mm (7.8 in) (Default).
Setting:
[TA.400]
Description:
Motorized traverse with a stroke of 400 mm. (15.6 in)
Setting:
[TA.600]
Description:
Motorized traverse with a stroke of 600 mm. (23.4 in)
Setting:
[TA.1000]
Description:
Motorized traverse with a stroke of 1000 mm. (39 in)