www.fmiproducts.com
112127-01C
33
trouBLesHootinG
Continued
OBSERVED PROBLEM POSSIBLE CAUSE
REMEDY
Gas odor even when control
knob is in OFF position.
1. Gas leak.
See Warning
statement, page 37.
2. Control valve defective.
1. Locate and correct all leaks
(see
Checking Gas Connec-
tions
, page 20).
2. Replace control valve.
Gas odor during combus-
tion.
1. Gas leak.
See Warning
statement, page 37
1. Locate and correct all leaks
(see
Checking Gas Connec-
tions
, page 20).
Dark residue on logs or
inside of burner system.
1. Improper log placement.
2. Air holes at burner inlet
blocked.
3. B u r n e r f l a m e h o l e s
blocked.
4. Improper vent configura-
tion.
1. Properly locate logs (see
Installing Logs, Lava Rock, and
Glowing Embers
, page 24).
2. Clean out air holes at burner
inlets. Periodically repeat as
needed.
3. Remove blockage or replace
burner.
4.
Follow venting configuration
instructions on pages 12
thru 16.