www.fmiproducts.com
112127-01C
23
instaLLation
Continued
8. Install base to the wall with screws pro-
vided with thermostat.
9. Move temperature adjustment back and
forth to insure the bi-metal is free from
restrictions.
10. Replace cover onto base. (Upon installa-
tion, thermostat must be allowed to sta-
bilize at room temperature for a minimum
of 30 minutes for proper operation.)
11. Set temperature adjustment to the de
-
sired setting. This thermostat has been
electronically calibrated at the factory. No
adjustment or leveling is necessary.
REMOVING/REPLACING GLASS
DOOR
You must remove glass door to install logs,
lava rock, and ember material. To remove
glass door, you must first remove the front
panel on stove body.
CAUTION: Do not operate
this burner system with a bro
-
ken glass door panel or without
the glass door panel securely
in place. For replacement part
information see
Replacement
Parts
, page 35.
1. If stove front panel is still installed, remove
2 bolts from bottom of stove and one from
the top of stove to remove front panel
(see Figure 37). For the Oxford stove the
middle grate will need to be removed to
remove the top bolt.
2. Remove screws from 2 tabs at top of glass
door while holding door securely keeping
it from falling forward (see Figure 38).
3. Grasp door by both sides and ease it up-
ward off of lower bracket (see Figure 38).
4. To replace glass door, follow the above
instructions in reverse.
Figure 37 - Removing Front Panel from
Stove (Oxford™ Model Shown)
Bolt
Bolt
Stove Front
Panel
Middle Grate
Figure 38 - Removing Glass Door from
Burner System
Screw
Glass
Door