www.fmiproducts.com
125568-01B
16
PRESSURE TESTING HEATER GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure
15, page 15).
2. Open main gas valve located on or near
gas meter for natural gas or open pro-
pane/LP supply tank valve.
3. Make sure control knob of heater is in the
OFF position.
4. Check all joints from gas meter to equip-
ment shutoff valve for natural gas or pro-
pane/LP supply to equipment shutoff valve
for propane/LP (see Figure 16, page 15 or
Figure 17, page 16). Apply noncorrosive
leak detection fluid to all joints. Bubbles
forming show a leak.
5. Correct all leaks at once.
6. Light heater (see
Operation
, page 23).
Check all other internal joints for leaks.
7. Turn off heater (see
To Turn Off Gas to
Appliance
, page 25 for Remote Ready
models or page 27 for Variable Remote
Models.
INSTALLING SWITCH (REMOTE
READY MODELS)
The AUTO/OFF/ON switch for this log set is in-
stalled into the small single log accompanying
this log set. This switch needs to be used only
if remote or wall switch is not being used.
Gas Meter
Figure 17 - Checking Gas Joints (Natural
Gas Only)
Control Valve
Location
Equipment Shutoff Valve
INSTALLATION
Continued
Connect the wires to the valve from the switch
assembly as shown in Figure 18.
INSTALLING OPTIONAL REMOTE
ACCESSORIES (REMOTE READY
MODELS)
Installing Remote Receiver
Remote control accessories are available
separately (see
Accessories
, page 40). Read
instructions shipped with remote control along
with instructions below before attempting
installation.
1. If unit is already installed in fireplace, con-
tinue with these instructions. If unit has not
been installed in fireplace, go to step 6 and
continue installation of remote accessory.
WARNING: Turn off heater
and let cool before handling any
part of heater. Make sure gas is
turned of to unit.
2. Carefully remove logs and set aside.
3. Locate mounting screws on sides of heat-
er base assembly and remove screws. Set
screws aside for reinstallation.
4. Disconnect gas line from heater base as
shown in Figure 11, page 13.
WARNING: A qualified ser
-
vice person must connect and
disconnect gas to heater. Follow
all local codes.
5. Remove heater base from fireplace.
6. If installed, disconnect AUTO/OFF/ON
switch wire from control valve at TPTH and
TH locations (see Figure 19).
7. Connect wires from hardware pack (with
remote receiver bracket) to control valve at the
TPTH and TH locations as shown in Figure 19.
Connect other ends of these wires to remote
receiver wires.
Note: Make sure excess wire does not
interfere with burner or pilot.
8. If heater was removed from fireplace
before installation of remote accessory, see
Installing Heater Base Assembly
on page 12 to
reinstall heater into fireplace. Test gas connec-
tion for leaks (see
Checking Gas Connections
,
page 15).
Figure 18 - Connecting Wires
Control Valve
To AUTO
Terminal
on Switch
To OFF
Terminal on