www.fmiproducts.com
125568-01B
28
VARIABLE REMOTE MODELS OPERATION
Continued
Figure 42 - Hand-Held Remote Control
ON/OFF
MODE
UP/ DOWN
Arrows
THERMOSTAT
LCD
Display
OPERATING REMOTE CONTROL
WARNING: Fireplace can
turn on suddenly. Keep away
from burner.
After lighting pilot, let pilot flame burn for about
one minute. Slide remote selector switch to
REMOTE position. You can now turn burner
on and off with remote.
IMPORTANT: Do not leave selector switch in
REMOTE or ON position when pilot is not lit.
This will drain batteries.
When any button is pushed on remote control,
LCD display will glow blue. Blue glow will go
off after several seconds if no action is being
taken with remote.
ON/OFF
Push ON/OFF button and burners will come
on in high position (see Figure 42). An
acoustic signal from the receiver confirms
the command.
Push ON/OFF button again and burners will
turn off.
A beep from receiver confirms the
command.
FLAME HEIGHT
This function allows you to control height
of flames through 5 levels
(see Figure 43)
.
Select manual flame height function by press-
ing MODE button until a flame is shown in
lower left corner of display. Use UP/DOWN
arrow button to set desired flame height (see
Figure 42). A beep from receiver confirms
the command.
SMART THERMOSTAT
The Smart Thermostat adjusts flame height
in accordance to differences between set
temperature and room temperature. As room
temperature gets closer to set temperature the
smart function will modulate the flame lower.
As room temperature cools, it will modulate
the flame higher.
ON
ON
MAX
Figure 43 - Remote Control Display of
Flame Height Minimum and Maximum
MINIMUM
MAXIMUM
ON
Figure 44 - Room Temperature Setting
Room
Temperature
Set
Temperature
ROOM THERMOSTAT
The remote control can operate as a room
thermostat. The thermostat can be set to a
desired temperature to control the comfort
level in the room.
To activate, press THERMOSTAT button on re-
mote control (see Figure 42). The word ON will
appear to the right of temperature bulb graphic
on display (see Figure 44). Use UP/DOWN
arrow button to set desired room temperature.
Control system will cycle fireplace on or off to
maintain selected temperature.