www.fmiproducts.com
56131J
7
0"
36"
2"
Wall In Front Of Glass
36" Min.
Perpendicular
Wall 2" Min.
From Opening
Right Side
Surround
(0" Min.)
Left Side
Surround
(0" Min.)
TOP VIEW
Figure 6 - Mantel Clearances for
Peninsula and See-Thru Fireplaces
(Peninsula Shown)
21" Min.
15" Min.
12" Min.
4"
Min.
7" Min.
1
1
/
2
" Max.
UNIT
Spacer
2 x 4
Combustible
Material May
Be Used
Drywall (Gypsum
Board, Sheetrock, etc.)
Safe Zone for
Projection of
Combustible
Material
Woodwork, such as wood trims, mantels and
other combustible materials should not be
placed within 7" of the opening of fireplace
(see Figure 6).
Combustible material above projecting more
than 1
1
/
2
" from appliance’s front face must
not be placed less than 15" from opening
of appliance, (ref.
NFPA Standard 211 Sec.
7-3.3.3
)
PRE-INSTALLATION PREPARATION
Continued
Figure 5 - Minimum Clearances
(See-Thru Shown)
Combustible Material
Drywall
2 x 4
Stud
Minimum 1" Clearance from
Side (Only for See-Thru)
FRAMING
Once final location has been determined,
observing clearances for vent termination,
you may construct framing using dimensions
shown in Figures 7 thru 13 depending on your
particular installation
If appliance is to be installed directly on car-
peting, tile (other than ceramic), or any com
-
bustible material other than wood flooring, the
appliance must be installed upon a metal or
wood panel extending the full width and depth
of the appliance. There are three holes on
each side of the bottom of unit where screws
can be used to secure unit to floor.
Figure 7 - Rough Opening for Installing
Peninsula Fireplace
39
3
/
4
" Min.
40
1
/
2
"
23
5
/
8
"
39
3
/
4
"
Min.
40
1
/
2
"
23
5
/
8
"
*
Figure 8 - Rough Opening for Installing
Peninsula Fireplace on Platform
* As required by design as long as
ceiling clearance is maintained.
Platform
Must Be
Solid, Flat,
and Fully
Supported