VENTING INSTALLATION

Continued

  WARNING:  Do  not  recess 

vent termination in to any wall. 

This will cause a fire hazard.

 

Combustible  Exterior  Wall: 

For  vinyl 

siding, stucco, or wood exteriors, a siding 

standoff must be installed between vent 

cap  and  exterior  wall.  Siding  standoff 

prevents excessive heat from damaging 

siding  materials.  Siding  materials  must 

be  cut  to  accommodate  standoff.  Bolt 

vent cap to standoff. Apply non-hardening 

mastic around outside edge of standoff. 

Position  standoff/cap  assembly  in  the 

center of square hole and attach to exte

-

rior wall with wood screws provided (see 

Figure 20). Siding standoff must sit flush 

against exterior fascia material.

5. 

Connecting Vent Cap with Horizontal 

Vent Pipe: 

Slide wall firestop over vent 

pipe before connecting horizontal run to 

vent cap (see Figure 21).

6.  Make  final  connection  to  vent  terminal. 

 

Flush or recessed with short vent sys-

tem:

 Vent system may be pre-sized. Check 

for final fit and slide unit into framing with 

firestop in place. This is helpful when using 

rigid pipe and round vent termination. Vent 

may be preconnected and slipped through 

firestop. Make sure 45° connection at unit 

is tight and does not come loose before 

unit is nailed to framing.

 

Square vent or long vent configuration:

 

Vent pipe must be manipulated at outer 

end to make final connection. Manually 

secure pipe inside open framing. If this 

is a retrofit installation in an inaccessible 

space,  you  may  have  to  secure  outer 

end of vent pipe with wall straps and tap 

screws at outer end.

 

When  using  tap  screws  with  rigid  pipe, 

be  sure  that  screws  do  not  penetrate 

inner pipe. These procedures may also 

be followed by flexible pipe installations. 

To use flexible pipe, vent must be drawn 

through end firestop, cut back to 6"-8" to 

permit easy connection of flex termination 

and connection must be slipped back into 

and secured to installation. You must use 

an adequate number of spring spacers at 

ends and closest bend to termination to 

prevent kinks or collapsing on the fire. Do 

not use screws with flex pipe. Vent system 

must  be  code  inspected  and  released 

before  adding  dry  wall  or  other  surface 

treatments.

Figure 20 - Installing Vinyl Siding 

Standoff (Combustible Exterior Wall)

Cut Vinyl Siding 

Away to Fit Standoff

Wood 

Screw

Bolt

Standoff

Vent 

Cap

Apply Mastic to 

All Four Sides

Vent Cap (Horizontal 

Termination)

Interior Wall 

Surface

Interior Wall Firestop 

(Combustible 

Exterior Wall Only)

Horizontal 

Vent Pipe

Figure 21 - Connecting Vent Cap with 

Horizontal Vent Pipe

Screw

Summary of Contents for DVF36

Page 1: ...tch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Inst...

Page 2: ...ny solid fuels in these appliances State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts WARNING Thisproductcon tainsand orgener...

Page 3: ...Do not modify this fireplace under any circum stances Any parts removed for servicingmustbereplacedprior to operating fireplace DANGER Carbonmonoxide poisoning may lead to death Before beginning the...

Page 4: ...ormance problems do not use propane LP fuel tank of less than 100 lbs capacity 2 If you smell gas shut off gas supply do not try to light any appliance do not touch any electrical switch do not use an...

Page 5: ...1 2 3 22 5 8 34 3 4 TOP VIEW Left Side Right Side Front Back 24 1115 16 101 2 11 2 11 2 111 8 Figure 1 Peninsula Dimensions Figure 2 See Thru Dimensions 10 Do not operate fireplace with glass door re...

Page 6: ...rements Determine the safest and most efficient loca tion for your FMI PRODUCTS LLC direct vent fireplace Make sure that rafters and wall studs are not in the way of the venting system Choose a locati...

Page 7: ...Figure 5 Minimum Clearances See Thru Shown Combustible Material Drywall 2 x 4 Stud Minimum 1 Clearance from Side Only for See Thru Framing Once final location has been determined observing clearances...

Page 8: ...n 10 Square Min Figure 12 Rough Opening for Installing Exterior Vent Terminal Vertical Height Depends on Installation 26 3 8 Horizontal Length Depends on Installation 90o Elbow 45o Elbow Figure 13 Ven...

Page 9: ...1 also known as NFPA 54 These models are approved for use with FMI PRODUCTS LLC 5 8 Series rigid type direct vent pipe as supplied by FMI PROD UCTS LLC or with approved types of flexible vent pipe no...

Page 10: ...US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada 6 ft 1 83m minimum In US 3 ft 91 cm above if within 10 ft 3 m horizontally L...

Page 11: ...istance from fireplace flue outlet to ceiling Add ceiling thickness vertical rise in an attic or second story and allow for sufficient vent height above roof line You may use one or two 90 elbows in t...

Page 12: ...ing codes Note When installing in a chase you should insulate the chase as you would the outside walls of your home This is especially im portant in cold climates Minimum clearance between vent pipes...

Page 13: ...quare hole through combustible exterior wall 8 1 2 diameter hole if non combustible Frame as necessary Figure 17 Vent Pipe Connections Male Slots Female Locking Lugs Rigid Vent Pipe 4 Three types of v...

Page 14: ...on at unit is tight and does not come loose before unit is nailed to framing Square vent or long vent configuration Vent pipe must be manipulated at outer end to make final connection Manually secure...

Page 15: ...is not to be used with a vertical termination 1 Determine route your vertical venting will take If ceiling joists roof rafters or other framing will obstruct venting system consider an offset see Figu...

Page 16: ...g lumber the same size as ceiling joists If area above ceiling is an insulated ceiling or an attic nail firestop from top side This prevents loose insulation from falling into required clearance space...

Page 17: ...e If vent pipe passes through any oc cupied areas above the first floor including storage spaces and closets you must enclose pipe You may frame and sheetrock enclosure with standard construction mate...

Page 18: ...nting Configuration Using Two 90 Elbows Venting Installation Continued Vertical Termination Configurations Figures 29 through 32 show four different configurations for vertical termination These minim...

Page 19: ...e Galvanized P58 24 24 Section Double Wall Pipe Galvanized P58 12 12 Section Double Wall Pipe Galvanized P58 6 6 Section Double Wall Pipe Gal vanized High altitude installation Your FMI PRODUCTS LLC d...

Page 20: ...F 58 12 Roof Flashing 6 12 to 12 12 Pitch Galvanized S 58 Vinyl Siding Standoff Galvanized VT 58 Vertical Round Termination Gal vanized HHT 58 High Wind Round Horizontal Ter mination Kit Galvanized HT...

Page 21: ...e and is located on the lower right side of appliance see Figure 37 page 22 The variable speed controller is mounted on a magnetic base and may be positioned anywhere within an accessible distance beh...

Page 22: ...re 37 Connecting Blower Accessory to Power Supply For Optional Fan Kit From Blower Assembly 4 Connect white wire to control valve ter minal TH and red wire to TPTH Move remote select switch to the REM...

Page 23: ...ebox and surround of fireplace see Figure 43 Fireplace Installation Continued IMPORTANT The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any...

Page 24: ...as control valve is accessible from lower control compartment Two pressure taps are provided on gas control valve for a pressure gauge connection see Figure 44 O F F P I L O T ON L O HI P ILOT E A 16A...

Page 25: ...ce twig E across top of logs B a shown in Figure 51 11 When finished installing logs close glass door Make certain safety door switch is fully pressed by door frame before secur ing four 4 spring load...

Page 26: ...proper clearances are observed see Clearances page 6 IMPORTANT Louvered openings must not be obstructed and upper and lower panels must remain removable for Fireplace Installation Continued servicing...

Page 27: ...ng of burner and pilot as sembly In cleaning take care not to alter pilot or burner location Be sure appliance is cool before each maintenance session CAUTION Theapplianceand logs can get very hot Han...

Page 28: ...ure seam in gasket is placed in the down position 4 Replace screen assembly and top and bottom louvers FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not fol low these instructions exactly a f...

Page 29: ...TPTH TP TH Gas Control Knob Flame Adjustment Knob Position Indicator Figure 59 Millivolt Control Valve Figure 60 Pilot Thermopile Pilot Burner Piezo Ignitor Thermocouple Operation Continued TO TURN O...

Page 30: ...PEA A V DVF36TSTA A AND V DVF36TSTEA A Input Rating 35 000 23 300 Btu Hr Fuel Natural Gas Manifold Pressure 3 5 W C Minimum Supply Pressure 4 5 W C Maximum Supply Pressure 10 5 W C Orifice Size 0 4500...

Page 31: ...echnician replace pilot line 7 Replace control valve see Replacement Parts and Ac cesssories page 34 8 Tighten thermocouple or replace 1 Check wiring connection Refer to Wiring Diagrams page 33 1 Chec...

Page 32: ...hoses Con sult pipe fitter or plumber 2 Repeat lighting procedure several times to purge air from lines If unit will still not light contact a qualified ser vice and repair technician 3 Remove debris...

Page 33: ...STEP DOWN 120V AC 24V AC OFF WALL SWITCH SUPPLIED ON IGNITER ASSEMBLY D V2 G N L1 IND IGNITION CONTROL MODULE TS S1 SW V1 P GND J BOX RECEPTACLE OPTIONAL CONTROL REMOTE GRN BLK WHT GRN NOT SUPPLIED I...

Page 34: ...tude 117370 01 Have a qualified technician replace part Orifice Natural 23103 Propane LP 23104 Electronic GAS VALVE Natural 14428 Propane LP 14429 Have a qualified technician replace part Ignitor ASSE...

Page 35: ...45 Refractory Pieces Front Bottom 25854 Left Right Bottom 25856 Rear 25855 Front Bottom Left Right Bottom Rear For Peninsula and See Thru Piezo Ignitor 14261 Grate 11184 Parts and Accessories Continue...

Page 36: ...roduct and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic mater...

Reviews: