www.fmiproducts.com
56131J
27
bURNER FLAME ADjUSTMENT
Continued
Figure 56 - Burner Removal
2. Carefully remove log set intact and set
aside (see Figure 56, page 27).
3. Remove 2 screws holding burner to hearth
pan.
4. Slide burner forward off orifice and turn to
one side to clear opening in hearth pan.
Be careful not to bend or damage pilot or
ignitor element.
5. To reinstall burner, follow reverse steps
making sure air shutter on burner tube is
completely seated over orifice mount.
6. Replace log set. Close door and latch.
Reattach screen and louvers.
CAUTION: Make certain ori-
fice is fully inside venturi tube's
air shutter and that air shutter is
adjusted accordingly, see Figure
54, page 26.
When lit for the first time, appliance may emit
a slight odor for about 16 - 24 hours. This is
normal and is due to the “curing” of logs and
“burn-in” of internal paints and lubricants used
in the manufacturing process. Keep compart-
ments, logs, burners, and area surrounding
logs clean by vacuuming or brushing at least
twice a year. Temporary removal of log set
may ease cleaning of burner and pilot as-
sembly. In cleaning, take care not to alter pilot
or burner location. Be sure appliance is cool
before each maintenance session.
CAUTION: The appliance and
logs can get very hot - Handle
only when cool.
WARNING: Turn off gas and
wall switch before servicing
appliance. Any safety screen or
guard removed for servicing the
appliance must be replaced prior
to operating the appliance.
WARNING: Make certain
wires and gas lines are not
touching the underside of the
firebox.
Glass Door
Refractories
Grate and
Logs
Burner
Hearth Pan
Louver
Assembly
WARNING: Children and
adults should be alerted to the
hazards of high surface tem
-
peratures, and to stay away from
the appliance to avoid burns or
clothing ignition. Young children
should be carefully supervised
when they are in the same room
as the appliance.
WARNING: Have a qualified
agency periodically inspect the
vent system at the start of each
heating season, for any obstruc
-
tion which may hinder its normal
operation. Never obstruct the flow
of combustion and ventilation air.
Keep the front of the appliance clear
of all obstacles and materials.
CAUTION: Label all wires
prior to disconnection when
servicing controls. Wiring errors
can cause improper and danger
-
ous operation.
OPERATING GUIDELINES AND MAINTENANCE