TROUbLESHOOTING
Continued
REMEDY
1. Check electrical connections
and replace wall switch
1. Clean and adjust main
burner
2. Adjust ignitor location for
maximum flame impinge-
ment on sensor
3. Have vent inspected for
blockage or damage
POSSIbLE CAUSE
1. Wall switch wires defective
1. Burner flame is too low
2. Igniter is misaligned causing
safety burner to "drop out"
3. Vent may be blocked or
restricted
ObSERVED PRObLEM
No gas to main burner when
wall switch and valve are set
to ON position
Frequent main burner outage
WIRING DIAGRAMS
GND
J. BOX
RECEPTACLE
GRN
BLK
WHT
GRN
(NOT SUPPLIED)
INCOMING
120V AC
(FUSE BOX
OR
BREAKER)
FIELD WIRE
WHT
BLK
CONNECTORS
Variable
Speed
Control
Blower
Electrical Rating:
120v, 60Hz, 0.7A
TRANSFORMER
STEP DOWN
120V AC
24V AC
OFF
WALL SWITCH
(SUPPLIED)
ON
IGNITER
ASSEMBLY
D V2
G
N
L1 IND
IGNITION CONTROL
MODULE
TS S1
SW V1
P.
GND
J. BOX
RECEPTACLE
OPTIONAL
CONTROL
REMOTE
GRN
BLK
WHT
GRN
(NOT SUPPLIED)
INCOMING
120V AC
(FUSE BOX
OR
BREAKER)
FIELD WIRE
WHT
BLK
CONNECTORS
E A
IH
LO
IPT
O
L
DO NOT
CONNECT
CONTROL
VALVE TO
120 VAC
GAS VALVE
Figure 63 - Electronic Wiring Diagram
Figure 64 - Optional Blower Wiring Diagram
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burner will have delayed ignition
• fireplace will not produce specified heat
• propane/LP gas supply may be low
You may feel your gas pressure is too low. If
so, contact your local gas supplier.
TECHNICAL SERVICE
You may have further questions about instal
-
lation, operation, or troubleshooting. If so,
contact FMI PRODUCTS, LLC at 1-866-328-
4537. When calling please have your model
and serial numbers of your heater ready.