www.fmiproducts.com
56131J
30
OPERATION
Continued
TO TURN OFF GAS
TO APPLIANCE
1. Turn off all electrical power to appliance
if service is to be performed.
2. Remove control access panel or louver.
3. Close gas valve.
SPECIFICATIONS
ELECTRONIC SySTEM
Continued
(V)DVF36TPNA-(A), (V)
DVF36TPNPEA-(A), (V)DVF36TSTA-
(A) AND (V)DVF36TSTEA-(A)
• Input Rating: 35,000/23,300 Btu/Hr
• Fuel: Natural Gas
• Manifold Pressure: 3.5" W.C.
• Minimum Supply Pressure: 4.5 W.C. **
• Maximum Supply Pressure: 10.5" W.C.
• Orifice Size (0-4500 ft.): #34 DMS
(V)DVF36TPNPA-(A), (V)
DVF36TPNPEA-(A), (V)DVF36TSTP-
(A) AND (V)DVF36TSTPEA-(A)
• Input Rating: 31,000/20,000 Btu/Hr
• Fuel: Propane/LP Gas
• Manifold Pressure: 10" W.C.
• Minimum Supply Pressure: 11 W.C. **
• Maximum Supply Pressure: 13" W.C.
• Orifice Size (0-4500 ft.): #51 DMS
**For purpose of input adjustment.