www.fmiproducts.com
56131J
22
FIREPLACE INSTALLATION
Continued
You may test blower for operation by turning
control knob clockwise just until it clicks on
which is the full on position. Adjust fan speed
to lowest setting (this should be no more than
1/4 of a turn clockwise).
FRONT
OFF
P
IL
O
T
ON
LO
HI
PI
LOT
E
A
16AI
7
TPTH
TP
TH
Figure 38 - Installing Remote Receiver
(HRC100)
Gas
Valve
To Thermopoile
Receiver Clip
Terminal
Wires
Plastic Mounting Clips
9-Volt Battery
White
Red
OPTIONAL WIRELESS HAND-HELD
REMOTE CONTROL INSTALLATION
Note: If using an optional wireless hand-
held remote control, wall switch is no longer
operational.
NOTICE: Only use alkaline bat
-
teries (not included).
Installing HRC100 Model Remote Control
(Millivolt Models Only)
1. Remove lower louver access panel in
fireplace (see step 1 of
Wall Switch Instal-
lation
, page 21).
2. Disconnect wall switch wires from termi-
nals marked TH and TPTH (see Figure
35, page 21).
3. Slide 9-volt battery into clip on back of
remote receiver and connect battery termi-
nals to battery. Mount receiver onto bracket
with clips provided (see Figure 38).
9-Volt Battery
Battery
Housing
Figure 39 - Installing Battery in Hand-
Held Remote Control Unit (HRC100)
Battery
Cover
Terminal
Wires
Remote Control Unit
Sensor
Tag
Figure 37 - Connecting Blower
Accessory to Power Supply
For Optional
Fan Kit
From Blower
Assembly
4. Connect white wire to control valve ter-
minal TH and red wire to TPTH. Move
remote select switch to the REMOTE
position.
5. Replace louvered access panel by follow-
ing reverse steps on page 21.
6. Remove battery cover on back of hand-
held remote (see Figure 39). Remove and
discard sensor tag.
7. Attach terminal wires to 9-volt battery.
Place battery into housing.
8. Replace battery cover onto hand-held
remote.
9. Set selector switch on receiver to the OFF
position if you will be away from unit for
an extended period of time.
Installing SKYTECH/WRC Model Remote
Control (Electronic Models Only)
1. Remove lower louver access panel in
fireplace (see step 1 of
Wall Switch Instal-
lation
, page 21).
2. If a wall switch was installed, it must be
removed from ignition control circuit for
remote to work properly. Remove wire
nuts from switch connection at ignition
control module. Using wire nut, connect
transformer (blue) wire to remaining wire
connected to control terminal marked
P.SW (see Figure 34, page 21).
3. The receiver does not require a battery.
To install, plug extension cord into one of
the outlet receptacles on outlet box. Plug
receiver unit into extension cord and igni-
tion module into receiver unit (see Figure
40, page 23).
4. Replace louvered access panel by follow-
ing reverse steps on page 21.
5. Activate handset battery by removing
insulating tab on back (see Figure 41,
page 23).