12
To stop charging:
Press the
Start/Stop
button for one second. The charger displays the
Home screen.
Note:
Pack data is lost when you leave Charging Mode, so if you want to see it, do so
before pressing the
Start/Stop
button.
Note:
If you restart the charge, you might see a
Please wait...
screen. The
charger is discharging capacitors, which may take up to one minute. When reinitializa
-
tion is complete, charging will begin again.
5. When charging is complete, the display below will appear, and the charger will beep for about
30 seconds to alert you.
Ch1
[chemistry]
DONE
Ch2
[chemistry]
DONE
To review final data for the pack(s):
Press the
Mode
button to cycle through the data
screens.
Note:
Pack data is lost when you leave Charging Mode, so if you want to see it, do so
before pressing the
Start/Stop
button.
To leave Charging Mode:
Press the
Start/Stop
button.
Alternate charging modes
Based on what the charger determines about charging conditions, it may enter one of these charg-
ing modes (as indicated in the display):
In
Low Voltage Restore Mode
, the charger automatically attempts to repair an overdischarged
pack. Cells discharged as low as 0.5V may be repaired to as much as 98% of capacity.
In
Safety Charging Mode
, the charger detects that at least one cell is seriously out of bal-
ance, and automatically lowers charge current to 0.5A.
CAUTION:
If the charger’s display shows
SAFETY CHARGING
during several
attempts at charging, the pack is damaged. Treat damaged packs with caution. Do not
charge them on a flammable surface, and do not charge them unattended.
In
Cold Weather Balancing Mode
, charging automatically stops at 4.10V/cell when tem-
perature is below 55°F to prevent cell damage.
If the charger detects a problem, it will stop charging and display a safety code. If this happens:
1. Press the
Mode
button to reset the charger.
2. Reconnect the battery properly.
3. Press the
Start/Stop
button to continue charging.