mounting to provide the required alignment accuracy. Avoiding or removing physical mounting limitations and
obstructions in the camera’s optical path, may also be required.
5.5 Network
The number of cameras in a network is only limited by the PC performance (required frames per second fps). This
means the need to consider the speed capability of the network card for transmitting the data and the performance
of the CPU for processing and displaying all data. For example, it would be possible to network 32 cameras or
maybe more cameras at 1 fps.
5.6 Cabling
Figure 5-2: Principal Cabling of Ethernet and Power Supply
Note
Before connecting and disconnecting any connector, make sure that the device is unpowered!
5.6.1 Ethernet M12 Cable
To connect the Ethernet M12 cable, follow the steps below:
•
Remove the rear metal sealed connector cap for the M12 connector at the rear side of the ThermoView
camera body
•
Attach the male M12 cable plug (2) straight into the female terminal (1) by turning the outer mounting
thread (3) in clockwise direction
•
Attach the RJ45 connector at the other end of the cable to the related device, like Ethernet switch,
computer, fiber optic converter or PLC.