MicroScanner Series
Cable Verifiers
Users Manual
18
Crossed Wires
Figure 10 shows that wires 3 and 4 are crossed. The the pin
numbers flash to indicate the fault. Cable length is
53.9 m. The cable is shielded.
Detection of crossed wires requires a far-end adapter.
EGK08.EPS
Figure 10. Crossed Wires
Crossed Pairs
Figure 11 shows that pairs 1,2 and 3,6 are crossed. The pin
numbers flash to indicate the fault. This crossed pair is likely
caused by mixing 568A and 568B cabling.
Detection of crossed pairs requires a far-end adapter.
Typical Causes of Crossed Pairs
•
Wires connected to wrong pins at connector or
punchdown block.
•
Mix of 568A and 568B wiring standards (12 and 36
crossed).
•
Crossover cables used where not needed (12 and 36
crossed).