background image

Installation Guide

 

8000-0975-01, Rev. F 

 1 

1

SensorNet 6-Position 

Junction Box (J-Box) 

 

This box provides power and data communications 
for up to six SpeedDome or SpeedDome Ultra 
camera domes. It also supports up to two outdoor 
domes (one per group of ports, P1–3 or P4–6) or a 
combination of up to one outdoor dome and three 
indoor domes, with the following restriction: if 
powering an outdoor dome, no other dome can be 
plugged into the same group of connectors (P1–3 
or P4–6). 

IMPORTANT:  Regulatory Requirements

 and 

other declarations on page 4.  

 

Figure 1.  J-Box Components 

 

 

Installation Requirements 

 

WARNINGS 

• 

NEVER PIERCE the enclosure. 

• 

This installation should be made by qualified 
service personnel and conform to the National 
Electrical Code and applicable local codes. 

• 

The product shall be located so as to provide 
protection against unintentional operation by 
employees, janitors and cleaners working 
about the premises, by falling objects, by 
customers, and by building vibration. 

The installation must satisfy the following 
requirements: 

• 

Follow the SensorNet Network Guide section 
to ensure proper network design. 

• 

Minimize exposure to environmental extremes 
by mounting the J-Box and the SpeedDome in 
a sheltered area when possible. 

• 

Always use dedicated, unswitched 24-hour AC 
power, supplied in accordance with local codes 
and with proper grounding. 

• 

Ensure that the J-Box's power On/Off switch 
and fuses are accessible. 

• 

Always use the four mounting bolts for wall 
and pole mount installations. 

• 

Use the clamp package provided when 
banding a camera dome to a pole. 

 

Installation Process 

Parts Required 

Installation Kit (0351-0739-01) includes: 

a)  Anchor, toggle and bolt, 1/4x4 

2880-0040 

b)  Anchor, wedge, bolt, 1/4x4 

2880-0052 

c) Screw, #10x1-1/24 

2812-7816 

d)  Flat washer, wide, type B, #10 

2848-9306 

e)  Conn, Plug Tublr, 1 x 4 Posn 

2109-0254-03 

f)  Conn, Plug, Tublr 1 x 5 Posn 

2109-0254-04 

g) Grommet, Edge, Continuous 

1ft  3100-0029-01 

h)  Bushing, STR RLF 

3100-0035-11 

 

A. Fuses 

G. Chassis 

B.  PC board (PCB) 

H.  TB1 connector 

C. Enclosure 

I.  Knockouts 

D. Mounting 

Bracket 

J.  Latch 

E.  Cover plate 

K.  TB2 connector 

F. On/Off 

switch 

 

 

K

 

Summary of Contents for RJ855AP

Page 1: ...ding vibration The installation must satisfy the following requirements Follow the SensorNet Network Guide section to ensure proper network design Minimize exposure to environmental extremes by mounting the J Box and the SpeedDome in a sheltered area when possible Always use dedicated unswitched 24 hour AC power supplied in accordance with local codes and with proper grounding Ensure that the J Bo...

Page 2: ...the chassis panel for details 1 Remove cover plate and chassis Figure 1 to access connector TB2 at rear of enclosure 2 Connect incoming AC wires to the TB2 connector for 115Vac or 230Vac operation using Figure 2 and its associated tables Figure 2 TB2 Power Connections N L Connecting Power to the PC Board 1 Replace the four screws that secure the chassis in the enclosure 2 Connect AC power to the p...

Page 3: ...ST AUX 5VDC AC PWR FALSE CD 123 456 AUX HOST P7 P8 3 2 1 3 2 1 3 2 1 3 2 1 HOST JW3 DOME 456 JW2 DOME 123 JW1 AUX JW4 3 2 1 3 2 1 3 2 1 3 2 1 HOST JW3 DOME 456 JW2 DOME 123 JW1 AUX JW4 Data and Power LED Indicators The LED indicators on the PCB see Figure 5 allow visual verification of SensorNet signals and power to the dome port and host auxiliary ports They illuminate to indicate the following c...

Page 4: ...a need for service or support Our dealers are fully empowered to provide the very best in customer service and support Dealers should contact American Dynamics at 800 507 6268 or 561 912 6259 or on the web at www americandynamics net WARRANTY DISCLAIMER Sensormatic Electronics Corporation makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied...