Using the Toner
49
Using the SmartTone Function
Use the SmartTone
™
function when you have trouble
locating a cable. This function changes the toner’s song
when you short a wire pair in the cable connected to the
tester. SmartTone works with the IntelliTone probe and
with analog probes.
Note
Use the SmartTone function only on dry pairs of
wires that are unterminated at both ends. Do not
use this function on powered wires.
1
Turn on the tester, then connect the tester to the cable.
2
MicroScanner
2
: Press
to select twisted pair or coaxial
cabling.
3
Press
or
until
appears on the display.
4
Press
or
to select the analog toner mode
(
IntelliTone
disappears from the display).
5
At the far end of the cabling, place the probe near the
ends of the cables.
6
Momentarily short a wire pair in a cable (twisted pair) or
short the conductor and shield in a cable (coaxial). If the
song changes when you release the short, you have
found the cable connected to the tester.
www.
GlobalTestSupply
.com
Find Quality Products Online at: