Endurance® Series
Users Manual
70
9.1.8. 24VDC, 1.1A, 100-240VAC power supply in NEMA 4/IP65 case (E-PS)
The terminal box is designed to provide IP65 (NEMA-4) protection to the terminal block, see
section 5.5, Electrical Installation of the Electronics Housing, and a power supply for the sensor.
The box should be surface mounted using the flanges and holes provided. It should be mounted
in such a manner to allow the free flow of air around the unit. Ambient temperatures should be
kept within the range of 0 to 50°C (32 to 120°F).
Technical data for the power supply:
AC input
100
– 240 VAC 50/60 Hz
DC output
24 VDC / 1.1 A
Operating temperature
-20 to 60°C (-4 to 140°F)
Humidity
20 to 90%, non-condensing
Figure 50: 24VDC, 1.1A, 100-240VAC power supply in NEMA 4/IP65 case (E-PS)