Endurance® Series
Users Manual
66
9.1.2. Low Temp. Multi-conductor cable with M16 connector (E-2CLTCBxx)
Use the Low Temp. 12-wire multi conductor cable (E-2CLTCBxx) for wiring the Endurance
®
sensor with the 24 VDC power supply, all inputs, outputs, and the RS485 interface. It is a
shielded 12-conductor cable, made of 2 twisted pairs plus 8 separate wires, equipped with a
M16 DIN connector on one side and wire sleeves at the counter side. The cable is PUR
(Polyurethane) coated and withstands ambient temperatures from -40 to 105°C (-40°F to
221°F). PUR coated cables are flexible and have well to excellent resistance to against oil,
bases, and acids.
Purchasable Low Temp. 12-wire multi-conductor cables lengths are 4m (13ft.), 8m (26ft.), 15m
(50ft.), 30m (100ft.), 60m (200ft.), see Table 5.
Temperature:
-40 to 105°C (-40°F to 221°F)
Cable material
PUR- 11Y (Polyurethane), Halogen free, Silicone free
Cable diameter:
7.2 mm (0.283 in) nominal
Conductors:
Power supply
2 wires (black/red)
Conductor:
0.2 mm² (AWG 24), stranded tinned copper
Isolation:
PE- 2YI1
Shield:
none
RS485 interface
2 twisted pairs (black/white and purple/gray)
Conductor:
0,2 mm² (AWG 24), stranded tinned copper
Isolation:
PE- 2YI1
Shield:
CDV-15, 85% covered
Outputs and Ground
6 wires (green/brown/blue/orange/yellow/clear)
Conductor:
0,2 mm² (AWG 24), stranded tinned copper
Isolation:
PE- 2YI1
Shield:
none
Polyurethane (Isocyanate) may cause allergy and is under a cloud to cause
cancer!
If you cut the cable to shorten it, notice that both sets of twisted-pair wires
have drain wires inside their insulation. These drain wires (and the white wire
that is not part of the twisted pair) must be connected to the terminal labeled
CLEAR.
If you purchase your own High Temp. Multi-conductor cable, use wire with
the same specifications as herein mentioned. Maximum RS485 cable length
is 1.200 m (4000 ft). Power supply (24VDC) feed in distance to the Endurance
®
sensor should not extend the 60m (200 ft.) limit.
An ordered Multi-Conductor Cable does
not
include a terminal block!
Figure 44: Low Temp. Multi-Conductor Cable with M16 Connector (E-2CLTCBxx)