4. REMOTE OPERATION
Page
85
4.4
COMMANDS
4.4.1
PROGRAMMING MESSAGES
Some commands accept an optional suffix. This suffix can be used to specify the explicit Q-RPT
to address. In most cases, each Q-RPT in the RPM4 operates as an independent
measurement device. If the suffix is not specified, then the “Active” Q-RPT is assumed.
The “RANGE” or “ARANGE” command can be used to select the “Active” Q-RPT. There are
some limitations to use of the suffix when the RPM4 is in differential mode (see Section
3.3.3.1) or the “HL” Q-RPT is active (see Section 3.2.4). See the program message
descriptions for suffix use with a specific command.
Table 16.
Program Message List
COMMAND
‘
n
’ indicates an
optional suffix
DESCRIPTION
#
Send a command string out of the RPM4 COM2 port.
ABORT
Stop pending operations
ARANGE
n
Read or set a new AutoRange to use.
ATM
Read the current atmospheric pressure (on-board barometer).
AUTOZERO
n
Read or set the status of the AutoZ automatic zeroing function.
AUTOZERO
n=RUN
Run AutoZero.
CALAMB
Read or set the on-board barometer calibration
COM1
Read or set the configuration of the COM1 port.
COM2
Read or set the configuration of the COM2 port.
CONT
n
Enable continuous measurements
DATE
Read or set the current date.
ERR
Read the last error message.
GPIB
Read or set the GPIB interface address.
HEAD
Read or set the fluid head settings.
ID
Read or set the RPM4 alphanumeric asset ID tag.
L2
Selects “classic” program message format
L3
Selects “enhanced” program message format
LL
n
Read or set the lower limit for the current range (negative gauge and differential
modes only).
LOCAL
Return control to the RPM4 front panel.
MEM
Read the power-up memory test status.
MMODE
n
Read or change the active measurement mode.
MSGFMT
Read or set the type of program message format to use.
NVENT
n
Read or set the status of low vent valve (Gxxx or BGxxx Q-RPT only)
PCAL
n
Read or set the user Lo Q-RPT calibration information.
PCAL:
XX
Read or set the user Lo Q-RPT calibration information (old command).
PR
n
Read the next RPM4 pressure.
PRR
n
Read the next RPM4 pressure, rate, and ATM.
QPRR
n
Read the last RPM4 pressure, rate and ATM.
RANGE
Select a Q-RPT to be “active” in it’s default full scale range
RATE
n
Read the next available rate of change of pressure.
READRATE
n
Read or set the Q-RPT measurement read rate and mode
READYCK
n
Read or set a flag that is cleared by a
Not Ready
condition.
REMOTE
Enable remote local lockout operation.
RES
n
Read or set the pressure display resolution for the current Q-RPT and range.
RESET
Reset the RPM4 to default user parameters.
RPT
n
Read the available Q-RPT data.
SCRSAV
Read or set the front panel screen saver period.
SDS
n
Read or set the SDS state for a specific Q-RPT
SDSACT
Read or set the active Q-RPT SDS state
SDSAUTO
n
Read or set the SDS mode for a specific Q-RPT
SN
Read the serial number of the RPM4.
SR
n
Read the next available pressure status (
Ready/Not Ready
).
SS
n
Read or set the stability required for a
Ready
condition.
SS%
n
Read or set the stability required for a
Ready
condition (% span/ s).
TIME
Read or set the current time of day.
UCOEF
n
Convert a pressure in Pascal to pressure in the current units.
UDU
Read or set the user defined pressure unit.
Summary of Contents for RPM4
Page 10: ...RPM4 OPERATION AND MAINTENANCE MANUAL Page VIII N NO OT TE ES S...
Page 16: ...RPM4 OPERATION AND MAINTENANCE MANUAL Page VI N NO OT TE ES S...
Page 124: ...RPM4 OPERATION AND MAINTENANCE MANUAL Page 114 N NO OT TE ES S...
Page 144: ...RPM4 OPERATION AND MAINTENANCE MANUAL Page 134 N NO OT TE ES S...
Page 148: ...RPM4 OPERATION AND MAINTENANCE MANUAL Page 138 N NO OT TE ES S...