background image

 

Important Safety Instructions

 CAUTION

 – 

 Failure to follow the instructions may cause body injury or property damage. 

 

Grounding Instructions

 

DANGER

 – 

Improper use of the grounding plug can result in a risk of electric shock. 

 

SAVE THESE INSTRUCTIONS

If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to either flat 
blade terminal. The wire with insulation having an outer surface that is green with or without yellow 
stripes is the grounding wire. This product is factory equipped with a specific electric cord and plug to 
permit connection to a proper electric circuit. Make sure that the product is connected to an outlet 
having the same configuration as the plug. No adapter should be used with this product. Do not modify 
the plug provided — if it will not fit the outlet, have the proper outlet installed by a qualified electrician. 
If the product must be reconnected for use on a different type of electric circuit, the reconnection 
should be made by qualified service personnel.

This product should be grounded. In the event of an electrical short circuit, grounding reduces the risk of 
electric shock by providing an escape wire for the electric current. This product is equipped with a cord 
having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly 
installed and grounded.

1.

 Do not install or use the product in wet places as steam room etc.

2.

 It is recommended to use water-proof electrical outlet which should be lnstalled in the place where is not 

easily got wet.

3.

 This product should be used with 110V-120V,50/60Hz electrical current only,  load current is at least 15A. 

Power plug must be equipped with ground fault circuit interrupter or ground     fault electrical leakage protector 
or similar high sensitive, rapid type leakage switch (Rated sensitive current under 6mA).

4.

 When it thunders,it is strongly recommended to pull out the power plug.

5.

 Do not stand on ceramic toilet.

6.

 Ceramic toilet must install floor fixing bolt.

7.

 Do not stand on product unit,seat and cover.

8.

 Do not lean against the seat cover when using the product,to avoid damage. 

9.

 This product is equipped with soft-closing seal cover.Heavy pressing or pushing may damage the 

soft-closing damper.

10.

 Do not use lacquer thinner,petrol,liquid medicine,detergent,insecticide,toilet cleanser and scrubbing brush 

to clean the product.

11.

 Exposure to direct sunlight is prohibited.

12.

 Only use tap water or potable water;otherwise it may cause chafing.

13. 

Do not connect water supply to heater outlet.Make sure inlet water temperature at 3~35 

℃ 

/ 37.4~95 F

14.

 When the room temperature is under zero degree,please dry up the water tank,to avoid freezing. 

15.

 Raise rest room temperature to prevent the toilet from damage due to freezing.

16.

 When move the product from cold or wet environment into normal room temperature,wait for 2 hours until 

the condensation water is fully volatilized.Doing so can prevent the product from electrical short-circuit.

17. 

When not using the product over three(3) days,drain the water out of the container and pull the electrical 

plug from the wall outlet.

18. 

Stop using the product and shut off the power when product malfunctions,please contact the service 

people for professional service.

Summary of Contents for BID1000W

Page 1: ...uid bidet seat Product Handbook Instructions BID1000W...

Page 2: ...Installation Size and Preparation Tool 8 Installation of Main Unit 9 Preparation for start up 10 Daily Maintenance 11 Troubleshooting Guide 12 Warranty Card Installation of Baseplate Installation of...

Page 3: ...d or where oxygen is being administered 8 Connect this product to a properly grounded outlet only See Grounding Instructions 9 Do not throw cigarettes and other burning stuff into toilet otherwise it...

Page 4: ...easily got wet 3 This product should be used with 110V 120V 50 60Hz electrical current only load current is at least 15A Power plug must be equipped with ground fault circuit interrupter or ground fa...

Page 5: ...otection plug Whole set of product Power cord Infrared receiver Nozzle baf e Nozzle The remote control Buffer Lid Components Name Seat Release button Drying baf e Water supply pipe Front cleaning Rear...

Page 6: ...start rear cleaning function Rear cleaning Drying Stop drying automatically 2 During rear cleaning turn the knob forward the washing position moves forward otherwise the washing position moves backwa...

Page 7: ...er Automatic pressure discharging device Cleaning device 200W High temperature preventer thermal fuse If Applicable 6 level adjustment Over 0 2m min Warm wind speed Warm wind temperature Heating power...

Page 8: ...on screws 2 Expansion nut 4 Expansion nut 2 Manual including warranty card Remote control Remote control rack The remote control assembly Base plate assembly The lter assembly Certi cate of quality Ce...

Page 9: ...put it in a place prone to water Install base plate Toilet mounting holes Install mounting cardboard The black latch faces forward groove up Install the expansion nuts into the toilet mounting holes...

Page 10: ...oint Water Inlet pipe Current toilet water supply pipe Connect to the angle valve Connect to main unit ConnectTee joint to angle valve The originalTee joint should be removed Connect the inlet end of...

Page 11: ...Turn the angle valve counterclockwise to adjust the opening to the maximum Tips when the valve is opened for the rst time the angle valve handle has a large torque 2 Power Connection Insert power lin...

Page 12: ...to prevent the damage of the nozzle rod and motor Maintenance of Main Unit Daily Maintenance 1 Turn off the power during maintenance of this machine 2 Wipe the dirty area with a soft cloth that is wr...

Page 13: ...If there is still no water coming out after pressing current limiting shaft use a at blade screwdriver to unscrew current limiting nut remove current limiting shaft and clean it with a toothbrush or...

Page 14: ...counterclockwise and use a at blade screwdriver to pry the clamp out of the slot Installation Install the quick released connector of water inlet pipe into the main unit and clip the clamp into the sl...

Page 15: ...e is set in normal temperature level In standby mode or power saving mode Power off Get stuck by impurities Power off No sitting in sensing area The battery of the remote control is installed in the o...

Page 16: ......

Page 17: ...by any of the following events including but without limitation 1 The user s negligence or mistake in operation unreasonable repair or alteration 2 Products are damaged by negligence or mistake during...

Page 18: ......

Page 19: ......

Page 20: ......

Reviews: