Fitting the smoke detector
Fitting the battery
Installation of smoke detector
Attention:
this intelligent smoke detector needs around 6 seconds to perform a test and an automatic calibra-
the smoke detector has gone into operating mode.
Functions:
Warning:
when in its intermission mode, the Flow smoke detector is non active and won’t
respond to any smoke formation.
Usage
Press the test button on the smoke alarm until the alarm signal sounds. Test the smoke
alarm once a week, after a period of absence, after cleaning the smoke alarm and test it
everytime its battery is replaced. The smoke alarm must be regularly vacuumed to remove
any dust particles and ensure optimal working condition.
Removal
Handle this battery as chemical waste. Do not throw away the smoke alarm as normal
household refuse, but hand it in to be recycled. Question your municipal environment
service to hand in possibilities for recycling.
waste time getting dressed and/or collecting valuables.
- Stay close to the ground in case of heavy smoke, breathe softly through a (wet) cloth.
Ask neighbors for help if necessary.
Screw mounting plate
into wall or ceiling
put cover into place by
turning it 30 degrees turned
Turn back up to secure smoke detector
Photoelectric Smoke Detector
FLOW SMOKE DETECTOR
Model:
1015027
XX
XXX-CPD-XXXXXXXX
EN 14604:2005
XXXX
Test the alarm for correct operation using the
test facility, whenever the battery is replaced.
Manufactured in China by:
Flow Products International b.v.
Madridstraat 8
1175RK Lijnden
the Netherlands
Production date:
xx/xx/xxxx
Replace smoke detector before:
xx/xx/xxxx
Use only the following batteries:
Battery 9V LR61 or 6F22
Photoelectric Smoke Detector
FLOW SMOKE DETECTOR
Model:
1015027
XX
XXX-CPD-XXXXXXXX
EN 14604:2005
XXXX
Test the alarm for correct operation using the
test facility, whenever the battery is replaced.
Manufactured in China by:
Flow Products International b.v.
Madridstraat 8
1175RK Lijnden
the Netherlands
Production date:
xx/xx/xxxx
Replace smoke detector before:
xx/xx/xxxx
Use only the following batteries:
Battery 9V LR61 or 6F22
Replacing battery
The smoke alarm works with a 9V DC block battery. When dealt with under normal
circumstances, the average life time of this battery is one year. in case of an (almost) empty
lamp. This happens simultaneously every 30 to 40 seconds for a minimum of 7 days.
Replace itsbattery when this signal occures.
Warning:
Removing the battery causes the smoke alarm to stop working.
Fit the smoke detector on the
wall or ceiling with tape.
30 cm
Minimum
Ceiling
Wall
Best here
Never
install here
alarms in all rooms and areas of the house.
Livingroom
Landing
Kitchen
Bedroom
Bedroom
Bathroom
Heat alarm
Basement
Kitch-
en
Bedroom
Bedroom
Living
Room
Hall
Hall
Connect the battery
Fit the battery
Operating mode:
the red LED indication flashes every 50 seconds, meaning the device is opperating
correctly.
Alarm:
the red LED indication light flashes continuously along side the audible alarm that is being
transmitted: smoke is detected.
Testing:
you can test the smoke detector when it’s in its operating mode, press the button until the
LED indication flashes and the sound alarm is being transmitted. Release the button to stop testing.
Error:
errors are indicated by the red LED indication light flashing 5 times simultaneously to 5 audible
beeps sounding every 20-30 seconds.
Low voltage:
the red LED indication light flashes once, simultaneously to1 beep sounding every
30-40 seconds.
Lifetime:
the red LED indication light flashes 3 times, simultaneously to 3 audible beeps sounding
every 50-60 seconds.