If the alarm has been modified, dismantled, contaminated, damaged, 

neglected or otherwise abused or altered following the date of purchase,

• 

If it fails to operate due to incorrect siting, installation or maintenance

• 

Damage caused by failure to abide by the instructions supplied.

It is specifically drawn to the users attention that substantial periods in alarm will 

shorten alarm life, during which time the fire alarm will have provided valuable 

protection; no Claim under the guarantee will be entertained. The liability of 

UltraFire, arising from the sale of this alarm or under the terms of this guarantee 

shall not in any case exceed the cost of replacement of the alarm. In no case, 

shall UltraFire be liable for consequential loss or damage resulting from the failure 

of the alarm or the breach of this or any other guarantee, express or implied or for 

damage caused by failure to abide by the instructions supplied.

This guarantee does not affect your statutory rights.

UltraFire

33 West Street, Alford, Lincolnshire, LN13 9FX, United Kingdom

Telephone: 0800 978 8262

Email: [email protected]

UltraFire

ULLS10RF 2797-CPR-749677

BS EN 14604:2005 KM 623822

10

 

Yea

r

 

Batter

y

 

L

ife

10

 

Year

 

Bat

ter

y

 

L

ife

6. 

Screw the pattress to ceiling using the fixings provided. You may also use 

two half-moon shaped and double sided fixing pads.

7. 

Alternatively, you may use any proprietary builders fixing adhesive 

normally used to fix skirting boards and other light building components 

to walls etc.

NOTE: Be sparing with any adhesives used on the back of the radio pattress 

to avoid excess adhesive squeezing through holes onto the circuit board. 

When using adhesive pads or adhesives make sure the surfaces are flake 

free, clean, dry and flat. Take care to use all appropriate Health and Safety 

precautions when fixing the pattress and alarm to their surface - in particular 

use appropriate access equipment, protect yourself from dust and wear eye 

protection.

Do not change any components of the system for those made by other 

manufacturers. Up to 15 alarms may be paired to the system.

WARNING: The electronic test button provides a full test of the alarms 

functionality. Do not try to test the alarm using either heat smoke or naked 

flame as damage will occur.

7. USER INFORMATION

Protect your Home Against Fire

 

Contact your local Fire Brigade for a home safety check, this information is free 

and will identify potential fire hazards in and around your home.

Make sure all occupants of the home know what a fire alarm sounds like. Prove 

and practise a fire escape plan and arrange a suitable and safe assembly point.

What to Do if the Alarms Sound 

 

Alarms sounds are as follows:

Full alarm indicating 

smoke and fire

Repeating series of 3 beeps every 

4 seconds with flashing light

Low battery

Single beeps every minute

Test button jammed

One beep every 11 seconds

Fault

Double beep every minute

Ensure everyone leaves the building as soon as possible.

• 

Do not run.

• 

Do not stop to collect belongs.

• 

If it is safe to do so, close all windows and doors as you escape to 

prevent the spread of fire.

• 

Smoke is the main cause of death from fire. If trapped inside the building, 

cover your mouth, conserve breath and crawl to safety.

Do not silence a fire alarm until you know the cause of the alarm and when all 

occupants are safely outside the building.

Silencing an alarm 

 

Do not silence a smoke alarm until you are certain there is no fire. The fire 

alarm that has detected a fire will be flashing its red light in the centre of the 

test button once every second, all other alarms in the system will just be 

sounding. 

To silence the fire alarm system, press the test button on any alarm in that 

system. If one alarm continues to sound, it will be the one that has detected 

a fire. Check for a fire in its area and for its flashing red light. ONLY if you are 

certain there is no fire, press its test button to silence it. If you are not certain, 

evacuate the property and call your fire and rescue service on 999.

8. ALARM MAINTENANCE

A regular program of fire alarm maintenance will help to keep your alarm in good 

working order.

• 

Test the alarm weekly making sure that all interconnected alarms in the 

system sound within 10 seconds.

• 

Vacuum the alarms every six months and wipe them with a damp cloth.

• 

Do not paint the alarm.

A smoke alarm is a sensitive life-saving device. The life of this alarm can 

be significantly reduced by adverse environments, incorrect location and a 

failure to regularly clean and maintain it according to the instructions. Incorrect 

location and a lack of reasonable care may also cause it to malfunction and will 

invalidate the warranty.

9. TROUBLESHOOTING

The battery in the alarm will last ten years and the battery in the pattress will last 

ten years - they are both non-replaceable. At the end of its life the alarm will beep 

once every minute for a minimum of one month. The life of the battery can be 

significantly shortened by periods of storage or use in temperatures below 5°C or 

above 30°C. It will also be shortened by frequent or extended periods in full alarm 

often caused by conditions such as cigarette smoke, steam, aerosol spray and 

condensation. In these circumstances the warranty will be void. If this happens 

at night you can press the test button to silence the battery warning for 10 hours. 

Replace the alarm as soon as possible.

Problems are indicated in five ways;

1. 

The alarm beeps twice every minute indicating a malfunction.

2. 

The alarm beeps once every minute indicating a low battery.

3. 

The full alarm sounds for no reason. (A repeating series of three beeps with 

flashing light)

4. 

The alarm does not sound when pressing the test button.

5. 

The test button light remains steadily on or off. (i.e. does not flash 

approximately once every minute, when the unit is not in alarm) Inspect for 

obvious damage. Check that the alarm has been installed in accordance 

with the instructions. In the case of repeated nuisance alarms, check that 

it is free from dust, cobwebs and external contamination from such things 

as cigarette smoke, drying paint, spray from household aerosols and steam 

that will ultimately shorten the life of the alarm and invalidate the warranty. 

If this does not correct the problem, do NOT attempt to repair. There are no 

user serviceable parts internally. If the smoke alarm is within the warranty 

period and terms, indicate the nature of the problem and return the unit with 

proof of purchase to the address at the end of this manual. Units beyond 

warranty cannot be economically repaired.

10. PRODUCT WARRANTY

UltraFire guarantees to you, as a purchaser, that the enclosed fire alarm will 

be free from defects in material, workmanship or design under normal use and 

service for a period of 10 years. The enclosed Radio Pattress is guaranteed 

for 10 years. These Guarantees are not assignable. Our liability to you, under 

this guarantee is limited to repairing or replacing any part which we find to be 

defective in material, workmanship or design, free of charge to the customer, upon 

sending the alarm with proof of date of purchase, postage paid to 

UltraFire, 33 

West Street, Alford, Lincolnshire, LN13 9FX, United Kingdom

. The terms of this 

guarantee will not apply in the following circumstances:

USER MANUAL

ULLS10RF OPTICAL SMOKE 

ALARM WITH RADIO-INTERLINK

Optical Smoke 

Alarm

Radio-Interlinked

DOC 1482 - V1.0

Reviews: