![Flotec WATERPRESS 1000 Use And Maintenance Manual Download Page 9](http://html1.mh-extra.com/html/flotec/waterpress-1000/waterpress-1000_use-and-maintenance-manual_2307690009.webp)
GB
The pump cannot be used for sea water and inflammable, corrosive, explosive or
dangerous liquids.
Verify that the electropump never runs without liquids.
WARNING
WARNING
Ch. 3 Installation (see Fig. 1)
When installing, please ensure electropump is disconnected from electrical supply.
Pumps in this series are not suitable for use in a swimming pool and the relevant
cleaning and servicing operations. These autoclaves cannot be used close to
fountains, garden ponds or similar locations.
Protect the electropump and all pipes from bad weather or freezing conditions
WARNING
To prevent possible injuries to people, avoid inserting hands into the mouth of the pump if
this is connected to the mains.
DANGER
7
GB
2
Electric shock
risk
DANGER
Sound emission values obtained in conformity with the EN 12639 standard
* Measurement method according to EN ISO 3746
Technical Data
WATERPRESS 1500 WATERPRESS 1000
Mains voltage / frequency
230 V ~ 50 Hz
230 V ~ 50 Hz
Absorbed power
1100 Watt
800 Watt
Type of protection / Insulation class
IP X4
IP X4
Suction fitting
33,25 mm (1"F)
33,25 mm (1"F)
Delivery fitting
33,25 mm (1"F)
33,25 mm (1"F)
Maximum flow rate
4.800 l/h
3.300 l/h
Maximum head
50 m
46 m
Maximum suction height including load losses
7 m
7 m
Power cable
1,5 m H07 RNF
1,5 m H05 RNF
Weight
30 Kg / 22,3 Kg
14,8 Kg
Maximum dimension of pumped solid particles
3 mm
3 mm
Maximum admitted working pressure
6 bar
6 bar
Minimum ambient temperature
5° C
5° C
Maximum ambient temperature
40° C
40° C
Maximum temperature of the pumped fluid
50° C
50° C
Maximum number of starts per hour, uniformly distributed
40
40
Sound power level (Lwa) *
85 dB
81dB
Sound pressure level (Lpa)
73,2
72,8
Technical Data
WATERPRESS 750
Mains voltage / frequency
230 V ~ 50 Hz
230 V ~ 50 Hz
230 V ~ 50 Hz
Absorbed power
800 Watt
600 Watt
1200 Watt
Type of protection / Insulation class
IP X4
IP X4
IP X4
Suction fitting
33,25 mm (1"F)
33,25 mm (1"F)
33,25 mm (1"F)
Delivery fitting
33,25 mm (1"F)
33,25 mm (1"F)
33,25 mm (1"F)
Maximum flow rate
3.300 l/h
2.700 l/h
4.300 l/h
Maximum head
46 m
43 m
50 m
Maximum suction height including load losses
7 m
7 m
7 m
Power cable
1,5 m H05 RNF
1,5 m H05 RNF
1,5 m H07 RNF
Weight
13,8 Kg - 21,5 Kg
13,8 Kg
15 Kg
Maximum dimension of pumped solid particles
3 mm
3 mm
≤
2 mm
Maximum admitted working pressure
6 bar
6 bar
6 bar
Minimum ambient temperature
5° C
5° C
5° C
Maximum ambient temperature
40° C
40° C
40° C
Maximum temperature of the pumped fluid
50° C
50° C
50° C
Maximum number of starts per hour,
uniformly distributed
40
40 40
Sound power level (Lwa) *
85 dB
78 dB
82 dB
Sound pressure level (Lpa)
72,7
69,7 70,1
WATERPRESS INOX 1000
WATERPRESS
INOX 1600
Summary of Contents for WATERPRESS 1000
Page 60: ...58 GR 2 1 4 3 4 5 Teflon 4 D 30 mA DIN VDE 0100T739 FL EC 3 HO7 RN F 5 1 GR 3 8...
Page 61: ...59 2 8 9 1 230 V FL EC FL EC 2 bar 3 bar 6 GR GR 4 7 FL EC 8...
Page 93: ...Fig 1 91...
Page 95: ......
Page 96: ......