Manual MCS-64 Page 23
Index
Sub-
index
Name
Type
Attri-
bute
Default-value
Meaning
2900 -
293F
for
LDM
0..63
0
1
2
3
4
5
6
7
8
9
10
11
Number of entries
Gross weight
Net Weight
Tare
Dosed weight
Dosed tare
Average weight
A/D sample
H&B Device ID
H&B FW Version
Device Status
ADC Reference
UI8
I32
I32
I32
I32
I32
I32
I32
I32
I32
I32
I32
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
11
Number of entries in info array.
Weight and info values as 32 bit signed integer
2A00 -
2A3F
for
LDM
0..63
0
1
2
3
Number of entries.
Mass Flow Value.
Mass Flow Trend.
Total Mass.
UI8
REAL32
REAL32
REAL32
ro
ro
ro
ro
3
Number of entries in the mass flow data
Mass Flow Value.
Mass Flow Trend.
Total Mass.
2B00 -
2B3F
for
LDM
0..63
0
1
2
3
4
5
Number of entries.
Decimal Point.
Scale.
dTime.
dWeight.
Delay after refill
UI8
I32
I32
I32
I32
I32
ro
rw
rw
rw
rw
rw
5
Number of entries in the mass flow parameters.
The decimal point for the Flow value.
The scale (see below).
Delta Time measuring window.
Delta Weight measuring window.
Delay after refill.
Scale:
0,1,2 :
d/sec, d/min, d/hour,
3,4,5 :
1000 d/sec, 1000 d/min, 1000 d/hour,
6,7,8 :
1000000 d/sec, 1000000 d/min, 1000000 d/hour.
2BFF
Number of entries.
As for 2B00-2B3F
UI8
I32
ro
wo
5
Number of mass flow parameters.
As for 2B00 – 2B3F, except this is WRITE ONLY and the settings are
broadcasted to all LDMs.