Fig. 4
b. Check if the cable
С
9997065
В
Steel rope 7x7 1 mm is frayed and if there is the stop
С
9997816
С
Cable stop 1806-Z ni at the cable attachment to the Cabin heater choke
КА
7040200. Fig. 4.
c. If the stop
С
9997816
С
(Cable stop 1806-Z ni) is missing, connect the cable
С
9997065
В
(Steel rope 7x7 1 mm) to the Cabin heater choke as shown at the Fig. 4 and fix it fix it by the
stop
С
9997816
С
(Cable stop 1806-Z ni) using a screwdriver.
d. Remove the panel from the instrument board using 3 hex-nut wrench and check the cable
С
9997065
В
(Steel rope 7x7 1 mm) for fraying and if there is the sleeve
С
9997056
Е
(Nicopress stop sleeve 1.5-1.7 mm for 1.6 mm cable) at the cable attachment to the handle.
Fig. 5.
e. If the sleeve
С
9997056
Е
(Nicopress stop sleeve 1.5-1.7 mm for 1.6 mm cable) is missing,
connect the cable
С
9997065
В
(Steel rope 7x7 1 mm) to the handle and secure it with the
sleeve
С
9997056
Е
(Nicopress stop sleeve 1.5-1.7 mm).
f. If frayed, replace the cable to a new one
С
9997065
В
(Steel rope 7x7 1 mm), 59 in. / 1.5 m
long. While replacing the handle must be pushed in (Fig. 2,
а
):
g. Remove the damaged cable, secure a tip of the new cable by the sleeve
С
9997056
Е
(Nicopress stop sleeve 1.5-1.7 mm for 1.6 mm cable) using a Nicopress tool for rope 0.45 -
2.00 mm. Fig. 5.