Maintenance and Inspection Procedures Manual
Type:
CT
Series:
CTLS
LSA
Page: 4-84
AF 04800001
Revision No. 3
Date: 14 Sep 2008
4.3.4.7 Verification of Stabilator Installation and Adjustment
Check stabilator deflection per section 4.2.1.7.
Check trim tab deflection per section 4.2.1.7. For checking use template from Appendix I.
Check push-pull cable attachments C9997092 (Push-pull cable TIPO 70), Fig. 7, for presence of grease
Multipurpose plastic grease LITOL-24M
ТУ
0254-015-00148820-99 (Retinax EP 2. Alvania EP-2
(SHELL); Alvania Grease R3 (Petroleum Co, Ltd); Mobilgrease MP, Mobilux 3 (Mobil Oil Corp.);
Energrease LS 3 (British Petroleum Co.); Beacom 3 (Esso)).
Check all bolts for tightness and markup with anti-sabotage lacquer (Maraflor TK 36 art. C9990703).
Fig. 7