3

Place the drilling template on the front service panel 
under the draw spout so that the folded edge is placed 
along the service panel edge.  Tape the template in place 
or mark the hole to be drilled in front service panel. 

6

Install the door and spout asembly onto the freezer.

5

Install the valve, spring and cap to the door spout 
assmbly.  Then install the assembly onto the freezer door.

4

Install the panel mount connector on the panel, inserting 
the connector line through the hole.  Secure the 
connector from the inside of the panel with the nut 
provided.

8

7

Remove the panel and drill the 7/16” hole where marked.  
Deburr the hole if necessary.

ADPT TY80S-FCB2   FCB Auto Draw Valve Conversion Kit

REV021313

pg. 2 of 6

Install the Cylinder Assembly on the modified door spout 
by sliding the bracket over the threaded portion of the 
door spout.  Install the draw handle pin assembly from the 
kit onto the Cylinder Assembly and tighten screw to 
secure.