14 |
P a g e
INTERNAL GLASS REMOVAL
Follow the procedures below to remove and install the internal ceramic glass (double glass fireplace configuration).
Note: Suction cups are needed to remove the glass.
Warning!
Turn off the fireplace and allow time for the unit to cool before attempting to remove the glass.
CAUTION
:
The ceramic glass is very fragile and should be handled with care.
CAUTION
: Do not operate the appliance with glass removed, cracked or broken. Replacement of the panel(s) should
be done by a licensed or qualified service person
Step 1
–
Attach glass suction cups to the glass. Remove the glass
’
lower magnetic trim
. Place the trim in a secure
place. Any unit above 45
” requires 2 suction cups to hold the glass.
Step 2
–
Release the
lower glass trim
. The lower trim bolts can be released by hand and should not require any tools.
Once bolts are released remove lower glass holder trim.
Step 3
–
Hold the glass suction cups and hand release trim bolt on the top. The trim does not need to be removed and
will only open to allow a gap for glass removal.
Step 4
–
Push the glass up and clear it from the bottom as shown
When putting the glass back, DO NOT overtighten the bolts or glass may break
Step 1
Step 2
Summary of Contents for Corner Right & Left 120
Page 65: ...65 P a g e COMBUSTIBLE FINISHING MATERIAL CLEARANCES ...
Page 71: ...71 P a g e EXAMPLES OF HEAT RELEASES ...
Page 77: ...77 P a g e ELECTRIC AND CONTROL ELECTRIC DIAGRAM SCREEN MV MV PV PV ...
Page 78: ...78 P a g e ELECTRIC DIAGRAM DOUBLE GLASS OR PV Double Glass Fan Plug No use MV MV PV PV ...
Page 80: ...80 P a g e ELECTRIC DIAGRAM PV SYSTEM Ports 49 47 are connected to J6 on fireplace main board ...